Gas Specifications - Waldorf 800 Series RN8910GE Installation And Operation Manual

Gas range electric static/convection oven
Table of Contents

Advertisement

Gas Specifications

- Australia:
Main Burner Injectors
Open Burner
Pilot Burner ('PF' Option Only)
Supply Pressure
Burner Operating Pressure (*)
Gas Regulator Cap Screw
- New Zealand):
Main Burner Injectors
Open Burner
Pilot Burner ('PF' Option Only)
Supply Pressure
Burner Operating Pressure (*)
Gas Regulator Cap Screw
- UK Only:
Category:
Flue Type:
Main Burner Injectors
Open Burner
Pilot Burner ('PF' Option Only)
Supply Pressure
Burner Operating Pressure (*)
Gas Regulator Cap Screw
- (*) Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart from
when carrying out Gas Conversion, if required. (Refer to information in this section for details).
Gas Conversion and Specifications
II
(20, 37).
2H3P
A
1.
Natural Gas (G20)
25
Natural Gas
LP Gas (Propane)
Ø 2.45mm
0.30
1.13 - 3.40 kPa
0.95 kPa
Natural Gas
Ø 2.45mm
0.30
1.13 - 3.40 kPa
0.95 kPa
Ø 2.30mm
0.30
20 mbar
9.5 mbar
Ø 1.50mm
0.20
2.75 - 4.50 kPa
2.6 kPa
LP Gas
Ø 1.50mm
0.20
2.75 - 4.50 kPa
2.6 kPa
Propane (G31)
Ø 1.40mm
0.20
37 mbar
26 mbar

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents