Gas Supply Requirements; Gas Connection - Waldorf GP8910GE Installation And Operation Manual

800 series gas griddle range electric oven
Hide thumbs Also See for GP8910GE:
Table of Contents

Advertisement

Specifications

Gas Supply Requirements

- Non CE Only (Australia / New Zealand):
Input Rating
(N.H.G.C.)
Supply Pressure
Operating Pressure

Gas Connection

- CE Only:
Appliance Classification
Category:
Flue Type:
Heat Input
Nominal
(nett)
Gas Rate
Nominal
(nett)
Supply Pressure
Burner Operating
Pressure
Gas Connection
*
Measure burner operating pressure at gas control valve outlet test point (See Fig 3) with one
griddle burner operating at 'High' setting.
appliance regulator and is not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to 'Gas Conversion' section for details).
Gas Connection
Gas supply connection point is located 130mm from right hand side of appliance, 32mm from rear,
655mm from floor and is entered from beneath appliance. An optional underside connection is
available.
Connection is ¾" BSP male.
Natural Gas
GP8910GE/GEC
GP8121GE/GEC
80 MJ/hr
108 MJ/hr (102,364
(75,825 BTU)
1.13 - 3.40 kPa
(4.5" - 13.5" w.c.)
0.90 kPa (*)
(3.6"w.c.)
II
2H3P.
A
1.
Natural Gas (G20)
GP8910GE/GEC
GP8121GE/GEC
21 kW
3
2.22 m
/hr
3.02 m
20 mbar
8.2 mbar (*)
4
GP8910GE/GEC
80 MJ/hr
BTU)
(75,825 BTU)
¾" BSP Male
GP8910GE/GEC
28.5 kW
21 kW
3
/hr
1.63 kg/hr
3
/
" BSP Male
4
Operating pressure is ex-factory set, through
LP Gas (Propane)
GP8121GE/GEC
108 MJ/hr
(102,364 BTU)
2.75 - 4.50 kPa
(11" - 18.0" w.c.)
2.6 kPa (*)
(10.2" w.c.)
Propane (G31)
GP8121GE/GEC
28.5 kW
2.21 kg/hr
37 mbar
26 mbar (*)