Gas Supply Requirements - Waldorf RNB8110GE Installation And Operation Manual

Gas target top range electric ovens
Table of Contents

Advertisement

Specifications

Gas Supply Requirements

- Australia:
Input Rate (N.H.G.C.)
Gas Supply Pressure
Burner Operating Pressure (*)
Gas Connection
- New Zealand:
Input Rate (N.H.G.C.)
Gas Supply Pressure
Burner Operating Pressure (*)
Gas Connection
- UK Only:
Category:
Flue Type:
Heat Input (nett)
Gas Rate (nett)
Supply Pressure
Burner Operating Pressure (*)
Gas Connection
*
Measure burner operating pressure at target top hob manifold test point with target top burner
(Inner and Outer Ring) operating at full setting. Operating pressure is ex-factory set through
appliance regulator and not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to 'Gas Conversion' section for details).
Natural Gas
45 MJ/hr
1.13 - 3.40 kPa
1.0 kPa
Natural Gas
45 MJ/hr
1.13 - 3.40 kPa
1.0 kPa
II
2H3P.
A
1.
Natural Gas (G20)
11.5 kW
Nominal
4.7 kW
Reduced
200W
Pilot
1.22 m
Nominal
0.50 m
Reduced
0.02 m
Pilot
20 mbar
9.9 mbar
LP Gas (Propane)
45 MJ/hr
2.75 - 4.50 kPa
2.60 kPa
3
/
" B.S.P. Male
4
LP Gas
45 MJ/hr
2.75 - 4.50 kPa
2.60 kPa
3
/
" B.S.P. Male
4
Propane (G31)
11.5 kW
7.9 kW
3
/hr
0.89 kg/hr
3
/hr
0.61 kg/hr
3
/hr
0.02 kg/hr
37 mbar
26.8 mbar
3
/
" B.S.P. Male
4
4
200W