Gas Specifications - Waldorf RN8510GE Installation And Operation Manual

800 series gas ranges electric static/convection oven
Hide thumbs Also See for RN8510GE:
Table of Contents

Advertisement

Gas Conversion and Specifications

Gas Specifications

- Australia:
Main Burner Injectors
Open Burner
Pilot Burner ('PF' Option Only)
Main Burner
Griddle
Pilot Burner
Burner Aeration Setting
Supply Pressure
Burner Operating Pressure (*)
Gas Regulator Cap Screw
- New Zealand:
Main Burner Injectors
Open Burner
Pilot Burner ('PF' Option Only)
Main Burner
Pilot Burner
Griddle
Burner Aeration Setting
Supply Pressure
Burner Operating Pressure (*)
Gas Regulator Cap Screw
- UK Only:
Category:
Flue Type:
Main Burner Injectors
Open Burner
Pilot Burner ('PF' Option Only)
Main Burner
Griddle
Pilot Burner
Burner Aeration Setting
Supply Pressure
Burner Operating Pressure (*)
Gas Regulator Cap Screw
- (*) Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart from
when carrying out Gas Conversion, if required. (Refer to information in this section for details).
II
(20, 37).
2H3P
A
1.
Natural Gas (G20)
30
Natural Gas
LP Gas (Propane)
Ø 2.45mm
0.30
Ø 2.10mm
0.35
Fully Open
1.13 - 3.40 kPa
0.95 kPa
Natural Gas
Ø 2.45mm
0.30
Ø 2.10mm
0.35
Fully Open
1.13 - 3.40 kPa
0.95 kPa
Ø 2.30mm
0.30
Ø 2.10mm
0.35
Fully Open
20 mbar
9.5 mbar
Ø 1.50mm
0.20
Ø 1.30mm
0.23
Fully Open
2.75 - 4.50 kPa
2.6 kPa
LP Gas
Ø 1.50mm
0.20
Ø 1.30mm
0.23
Fully Open
2.75 - 4.50 kPa
2.6 kPa
Propane (G31)
Ø 1.40mm
0.20
Ø 1.30mm
0.23
Fully Open
37 mbar
26 mbar

Advertisement

Table of Contents
loading