Gas Specifications - Waldorf GP8910GE Installation And Operation Manual

Gas griddle range electric oven 800 series
Hide thumbs Also See for GP8910GE:
Table of Contents

Advertisement

Gas Specifications

- Australia / New Zealand Only
Main Burner
Pilot Burner
Griddle
Low Fire Adjustment
High Fire Adjustment
Operating Pressure
Gas Regulator Cap Screw
- UK Only
Appliance Classification
Category:
Flue Type:
Main Burner Injector
Pilot Burner Injector
Low Fire Adjustment
High Fire Adjustment
Operating Pressure
Supply Pressure
Gas Regulator Cap Screw
Note 1 The Gas Control Valve is fitted with a maximum flow bypass blanking screw, non
adjustable.
Note 2 The burner operating pressure is to be measured at the griddle gas control valve outlet test
point with one griddle burner operating at full setting. The operating pressure is ex-factory
set, through the appliance regulator and is not to be adjusted, apart from when carrying out
gas conversion, if required. (Refer to the 'Gas Conversion' section for details).
Gas Conversion and Specifications
Natural Gas
GP8910GE/GEC GP8121GE/GEC GP8910GE/GEC GP8121GE/GEC
3.00mm
0.41
1 full turn counter clockwise from the Fully 'IN' position
Maximum Flow Screw. Fully 'IN' (Note 1)
0.90 kPa (Note 2)
II
2H3P.
A
1.
Natural Gas (G20)
GP8910GE/GEC
GP8121GE/GEC
3.00mm
0.41
1 Full Turn Counter Clockwise from the 'Fully In' Position
Maximum Flow Screw. Fully In c.w. (Note 1)
8.2 mbar (Note 2)
20 mbar
27
LP Gas (Propane)
2.85mm
1.80mm
2.6 kPa (Note 2)
Propane (G31)
GP8910GE/GEC GP8121GE/GEC
2.85mm
1.80mm
26 mbar (Note 2)
1.70mm
0.25
1.70mm
0.25
37 mbar