Gas Specifications - Waldorf RNB8110GE Installation And Operation Manual

Gas target top range electric ovens
Table of Contents

Advertisement

Gas Specifications

- Australia:
Main Burner Injector (Inner Ring)
Main Burner Injector (Outer Ring)
Pilot Burner Injector
Burner Aeration Screw X (Inner)
Burner Aeration Screw Y (Outer)
Low Fire Adjustment
Operating Pressure
Gas Regulator Cap Screw
- New Zealand:
Main Burner Injector (Inner Ring)
Main Burner Injector (Outer Ring)
Pilot Burner Injector
Burner Aeration Screw X (Inner)
Burner Aeration Screw Y (Outer)
Low Fire Adjustment
Operating Pressure
Gas Regulator Cap Screw
*
Measure burner operating pressure at target top hob manifold test point with target top burner
(Inner and outer ring) operating at full setting. Operating pressure is ex-factory set through
appliance regulator and not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to details in this section for information).
Gas Conversion and Specifications
Natural Gas
Ø 1.70mm
Ø 2.60mm
0.35
25mm
28mm
1
2
/
turns out (ccw)
2
1.0 kPa (*)
Natural Gas
Ø 1.70mm
Ø 2.60mm
0.35
25mm
28mm
1
2
/
turns out (ccw)
2
1.0 kPa (*)
25
LP Gas (Propane)
Ø 1.10mm
Ø 1.55mm
0.25
25mm
28mm
1 turn out (ccw)
2.6 kPa (*)
LP Gas (Propane)
Ø 1.10mm
Ø 1.55mm
0.25
25mm
28mm
1 turn out (ccw)
2.6 kPa (*)