Gas Specifications - Waldorf GP8910GE Installation And Operation Manual

800 series gas griddle range electric oven
Hide thumbs Also See for GP8910GE:
Table of Contents

Advertisement

Gas Specifications

- Non CE Only (Australia / New Zealand):
Main Burner
Pilot Burner
Griddle
Low Fire Adjustment
High Fire Adjustment
Operating Pressure
Gas Regulator Cap Screw
- CE Only:
Appliance Classification
Category:
Flue Type:
Main Burner Injector
Pilot Burner Injector
Low Fire Adjustment
High Fire Adjustment
Operating Pressure
Supply Pressure
Gas Regulator Cap Screw
Note 1 Gas Control Valve is fitted with a maximum flow bypass blanking screw, non adjustable.
Note 2 Burner operating pressure is to be measured at griddle gas control valve outlet test point
with one griddle burner operating at full setting.
through appliance regulator and is not to be adjusted, apart from when carrying out gas
conversion, if required. (Refer to 'Gas Conversion' section for details).
Gas Conversion and Specifications
Natural Gas
GP8910GE/GEC
3.00mm
0.41
1 full turn counter clockwise from the Fully 'IN' position
Maximum Flow Screw. Fully 'IN' (
0.90 kPa (Note 2)
II
2H3P.
A
1.
Natural Gas (G20)
GP8910GE/GEC
3.00mm
0.41
1 Full Turn Counter Clockwise from the 'Fully In' Position
Maximum Flow Screw. Fully In c.w. (Note 1)
8.2 mbar (Note 2)
20 mbar
25
GP8121GE/GEC
GP8910GE/GEC
2.85mm
1.80mm
GP8121GE/GEC
GP8910GE/GEC
2.85mm
1.80mm
Operating pressure is ex-factory set,
LP Gas (Propane)
GP8121GE/GEC
1.70mm
0.25
Note 1
)
2.6 kPa (Note 2)
Propane (G31)
GP8121GE/GEC
1.70mm
0.25
26 mbar (Note 2)
37 mbar

Advertisement