5.10 Replacing the Elevation Gyro

1. Disconnect the gyro cable from the in-line connector.
Figure 5-14 Elevation Gyro
M2.5 Screws (x 2)
2. Remove the two M2.5 screws securing the gyro to the
LNB/feed tube assembly. Remove the old gyro.
3. Apply a drop of Loctite threadlocker to the threads of the
screws that you removed in Step 2. Install the new
elevation gyro and secure in place with the two screws.
4. Connect the new gyro cable to the in-line connector that
you disconnected in Step 1.
5. Calibrate the gyro as described in "Calibrating the Gyros"
on page 105.