Mellanox Technologies SX10XX Hardware User Manual page 71

1u switch systems
Table of Contents

Advertisement

Pin
Symbol Name
7
RS0
8
RX_LOS
9
RS1
10
VeeR
11
VeeR
12
RD-
13
RD+
14
VeeR
15
VccR
16
VccT
17
VeeT
18
TD+
19
TD-
20
VeeT
a. Circuit ground is internally isolated from chassis ground.
b. T
is an open collector/drain output, which should be pulled up with a 4.7k – 10k
FAULT
Ohms resistor on the host board if intended for use. Pull up voltage should be between 2.0V
to Vcc + 0.3V. A high output indicates a transmitter fault caused by either the TX bias cur-
rent or the TX output power exceeding the preset alarm thresholds. A low output indicates
normal operation. In the low state, the output is pulled to <0.8V.
c. Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V
d. Should be pulled up with 4.7kΩ – 10kΩ on host board to a voltage between 2.0V and 3.6V.
MOD_ABS pulls line low to indicate module is plugged in.
e. LOS is open collector output. Should be pulled up with 4.7kΩ – 10kΩ on host board to a
voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of
signal.
No connection required
Loss of Signal indication. Logic 0 indicates normal operation.
No connection required
Receiver Ground (Common with Transmitter Ground)
Receiver Ground (Common with Transmitter Ground)
Receiver Inverted DATA out. AC Coupled
Receiver Non-inverted DATA out. AC Coupled
Receiver Ground (Common with Transmitter Ground)
Receiver Power Supply
Transmitter Power Supply
Transmitter Ground (Common with Receiver Ground)
Transmitter Non-Inverted DATA in. AC Coupled.
Transmitter Inverted DATA in. AC Coupled.
Transmitter Ground (Common with Receiver Ground)