Masport Piccolo Installation Instructions Manual page 58

Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
1) The Trime kit allows for a 1/2" (13mm) of finish
facing material. The kit may be installed directly on
and/or against combustible building materials.
2) Frame in the enclosure for the Kit with framing
material. The framed opening for the assembled kit
is 33-1/2" (850 mm) high x 30-1/4" (769 mm) wide
x 16" (407mm) deep. See diagram.
3) For exterior walls vapour barrier and insulate the
enclosure to the same degree as the rest of the
house, or according to local installation codes. In
colder climates, if the heater is to be installed
against an exterior wall or chase, insulate the
exterior walls according to local installation codes.
4) Extend the vent chase to a minimum ceiling height
of 79" (2007 mm) at the same width and depth
mentioned above. Keep this area above the unit
clear of combustible construction except for the
framing header.
ZERO CLEARANCE KIT ASSEMBLY
Page 58
Warning: Combustible materials must not extend
inside the stand-offs on the side, top and rear
supports. For safety reasons do not modify or alter
any components of the 660-900 Kit.
1) Slide the front base assembly into position on the
main body assembly as shown in the diagram. Align
the screw holes with the 3 holes on the front side
supports. Align the nail holes on the front base
assembly base with the base of the main body
assembly.
2) Use the 3 screws (on each side) to tighten the main
body and front base assembly. Base must be at
same elevation as the main body assembly.
3) Nail the Zero Clearance Kit to the framing, there are
6 predrilled holes in the front face of the kit (3 per
side) and 3 predrilled holes in the front base
assembly. It is recommended that the front base
assembly and Main body base be nailed to the floor.
VENTING
This fireplace must be vented with a 4"(102mm)
diameter Class "B" vent

Hide quick links:

Advertisement

Table of Contents
loading