OPTIONAL OUTSIDE COMBUSTION AIR SUPPLY
A 4" (100 mm) dia. aluminum flex pipe or equivalent may be installed from the outside (with a proper exterior
cover) to the Zero Clearance cabinet. There are outside holes provided on three sides of the kit. Use only the
one that is most suitable for your installation. This will provide adequate outside combustion air supply to the
heater.
An authorized service person should install the gas line in accordance with all local building codes. If codes
permit, flex gas line or coiled copper tubing may be used as gas supply line. The suggested way to install the
gas supply line is as follows: run 1/2" (9.5 mm) NPT gas line to the left side of the framed opening. (See U31/
I31 installation instructions for additional information).
Natural Gas
Propane
Provide 120 VAC, 60 Hz (in Australia and New Zealand: 240 VAC, 50 Hzin) receptacle within 24"(610mm) of
the left side of the appliance (not inside the Zero Clearance Cabinet). Plug the cord on the appliance into the
receptacle.
ELECTRICAL
OUTLET BOX

GAS SUPPLY LINE

Specifications
Min. Inlet
Input
Gas Pressure
Rating
5" w.c.
30,000 Btu/h
1.13 kPa
31 mj/h
12" w.c.
27,500 Btu/h
2.75 kPa
28.5 mj/h

ELECTRICAL SUPPLY