Masport Piccolo Installation Instructions Manual page 35

Table of Contents

Advertisement

Note:
Any closets or storage spaces,
which the flue passes through
must be enclosed.
Offset Chart
INSTALLATION
PROCEDURES
for Masport AstroCap
TM
Flue System (Flex)
1) Locate the unit in the framing,
rough in the gas. Locate the
centerline of the termination and
mark wall accordingly. Cut a
254mm hole in the wall (inside
dimension).
Note: A 40mm clearance around the
liner must be maintained except
that only a 25mm clearance is
needed at the termination end.
We recommend framing a
254mm
x
254mm
dimensions) hole to give
structural rigidity for mounting
the termination.
Note: To make
the installation
more
aesthetically
pleasing, we
recommend
framing out a
square to
mount the
terminal to.
2) Level the fireplace and fasten it to
the framing using nails or screws
through the nailing strips.
3) Assemble the flue assembly by
applying Mill Pac to the 100mm
inner collar of the termination and
slipping the 100mm liner over it at
least 35mm. Fasten with the 3
screws (drilling pilot holes will make
this easier). Apply Mill Pac or high
temperature silicone to the 175mm
flex pipe and slip it over the 175mm
outer collar of the flue terminal at
least 35mm and fasten with the 3
screws.
NOTE:Horizontal sections must be
supported at intervals not
exceeding 900mm).
picture and performance will be
Direct
affected by sags in the liner).
4) Separate the 2 halves of the wall
thimble and securely fasten the
one with the tabs to the outside wall
making sure that the tabs are on
top and bottom. Fasten the other
thimble half to the inside wall. The
thimble halves slip inside each other
and can be adjusted for 2 x 4 or 2
x 6 walls. The liners must slip
over the collars a minimum of
35mm.
(inside
5) Slip the assembled liner and
termination assembly through the
thimble
termination cap faces up (there
are markings on the cap that show
which way is up). This will position
the termination cap with proper
down slope for draining water.
Fasten the cap to the outer wall
with the 4 supplied screws.
6) Pull the centre 100mm liner and
outer 175mm liner out enough to
slip over the flue collars of the
fireplace. (You may wish to cut the
liner shorter to make it more
workable.) Do not bend liner more
than 45
o
.
7) Apply Mill Pac over the fireplace
inner collar and slip the 100mm
liner down over it and attach with 3
supplied screws.
8) Do the same with the 175mm liner.
9) Apply a bead of silicone between
the thimble and termination and
around the outer edge of the
terminal at the wall in order to keep
the water out.
(Flame
IMPORTANT:
Do not locate termination
hood where excessive wind
may occur.
making
sure
the
Page 35