Miscellaneous System Fields - ADEMCO VISTA-20P Installation And Setup Manual

Hide thumbs Also See for VISTA-20P:
Table of Contents

Advertisement

FIELD
TITLE and DATA ENTRIES
Pager 3 Phone No.
*166
Enter up to 20 digits
Pager 3 Characters
*167
Enter up to 16 characters
Pager 3 Reports
*168
see pager 1 reports, field *162 for entries,
except use zone list 11.
Pager 4 Phone No.
*169
Enter up to 20 digits
Pager 4 Characters
*170
Enter up to 16 characters
Pager 4 Reports
*171
see pager 1 reports, field *162 for entries,
except use zone list 12.
Pager Delay Option for Alarms
*172
0 = none
1 = 1 minute

Miscellaneous System Fields

Clean Me Option
*174
0 = disable
1 = enable
Device Duration 1, 2
*177
0 = 15 secs
6 = 2-1/2 min #+12 = 8 min
1 = 30 secs
7 = 3 min
2 = 45 secs
8 = 4 min
3 = 60 secs
9 = 5 min
4 = 90 secs
#+10 = 6 min
5 = 2 min
#+11 = 7 min
50/60 Hz AC Operation
*181
0 = 60 Hz
1 = 50 Hz
EXPLANATION
VISTA-20P only.
If you enter fewer than 20 digits, exit by pressing [∗] and next field
number. To clear entries from this field, press ∗166∗.
VISTA-20P only.
See field ∗161 for explanation of entries. If fewer than 16 characters,
exit by pressing [∗] and next field number. To clear entries from this
field, press ∗167∗.
VISTA-20P only.
Enter the types of reports to be sent to pager 3 for each partition.
VISTA-20P only.
If you enter fewer than 20 digits, exit by pressing [∗] and next field
number. To clear entries from this field, press ∗169∗.
VISTA-20P only.
See field ∗161 for explanation of entries. If fewer than 16 characters,
exit by pressing [∗] and next field number. To clear entries from this
field, press ∗170∗.
VISTA-20P only.
Enter the types of reports to be sent to pager 4 for each partition.
This field determines the delay of alarm reports to the pager. This
gives the Central Station enough time to verify the alarm report that
2 = 2 minutes
it received, before the dialer attempts to dial the pager.
3 = 3 minutes
NOTE: The delay does not reset for new alarms occurring while an
existing pager delay is in progress.
This delay is for ALL pagers in the system.
This is a maintenance feature for ESL 2-wire smoke detectors
on Zone 1. If used, this option limits the number of smoke detectors to
a maximum of 10, rather than 16. To enable the "clean me" feature, a
time response setting of "3" (1.2 seconds) must be entered in ∗56 Zone
Programming for zone 1.
These entries set the duration for output action options 5 (duration
1) and 6 (duration 2) programmed in ∗80 Output Function
Programming.
#+13 = 10 min
#+14 = 12 min
#+15 = 15 min
Select the type of AC power applied to the control.
4-9