Miscellaneous System Fields

FIELD
TITLE and DATA ENTRIES
Daylight Saving Time
*77
Start/End Month
0 = Disabled
1 = Jan
2 = Feb
3 = Mar
Daylight Saving Time
*78
Start/End Weekend
0 = disabled
1 = first
2 = second
3 = third
Auto-Stay Arm
*84
0 = no
1 = partition 1 only
2 = partition 2 only
3 = both partitions
Cross Zone Timer (in seconds)
*85
0 = 15 secs
1 = 30 secs
2 = 45 secs
3 = 60 secs
4 = 90 secs
5 = 2 min
Cancel Verify
*86
0 = no
1 = yes
Misc. Fault Delay Time
*87
0 = 15 secs
1 = 30 secs
2 = 45 secs
3 = 60 secs
4 = 90 secs
5 = 2 min
Event Log Full Report Code
*89
0 = no report
1st digit non-zero = send report
Event Logging
*90
0 = no event logging
1 = log Alarm/Alarm Restore
2 = log Trouble/Trouble Restore
4 = log Bypass/Bypass Restore
8 = log Open/Close
x = log combination of events (add value of
entries)
4-6
4 = April
# + 10 = Oct
# + 11 = Nov
# + 12 = Dec
4 = fourth
5 = last
6 = next to last
7 = third to last
6 = 2-1/2 min #+12 = 8 min
7 = 3 min
#+13 = 10 min
8 = 4 min
#+14 = 12 min
9 = 5 min
#+15 = 15 min
#+10 = 6 min
#+11 = 7 min
6 = 2-1/2 min #+12 = 8 min
7 = 3 min
#+13 = 10 min
8 = 4 min
#+14 = 12 min
9 = 5 min
#+15 = 15 min
#+10 = 6 min
#+11 = 7 min
EXPLANATION
Enter the start and end month for daylight savings time, if applicable
to the region.
Enter the start and end weekend for daylight savings time, if
applicable to the region.
With this field enabled and system armed in AWAY mode at a
keypad (non-RF device), the system automatically reverts to armed
STAY (or INSTANT) mode if a door is not opened and shut within
the programmed exit delay time. An Opening report followed by an
Armed Stay report is sent to the Central Station. Any RF device that
arms the system AWAY overrides this feature and the system
remains armed in the AWAY mode.
Sets the maximum amount of time in which two cross zones must be
tripped in an armed system to send an alarm message to the Central
Station. If only one cross zone is tripped during this time, a trouble
message (CID code 380) for that zone is sent to the Central Station.
Assign cross zone pairs in zone list 4.
This option not for use in UL installations.
When enabled (1 = yes), this feature causes a "CANCELED ALARM"
display on the LCD keypad under the following conditions:
After the kissoff of the cancel message to the Central Station,
indicating a successful transmission.
When an alarm is successfully canceled before the Central Station
received the Alarm message. E.g., if an alarm is incorrectly
triggered and the user presses code + OFF before the dial delay
time has expired, the message will never go out to the CS.
When the Cancel report is not enabled and the system is disarmed:
a. before dialer delay expires (alarm report not sent) message
"Canceled Alarm" is displayed.
b. after dialer delay expires message "Canceled Alarm" is not
displayed .
Used with zones assigned to a configurable zone type with fault delay
on (configurable zone type digit "6"), and sets a zone response time of
15 seconds to 15 min. It can be assigned to zones with sensors that
provide a trouble indication when an oil tank is low, or similar
applications for critical condition monitoring where a non-alarm
response is desired.
UL: May only be used on non-burglar alarm and non-fire alarm zones
when used on a fire and/or UL burglar alarm installation.
If an Event Logging selection is made in field ∗90, a message can be
sent to the central station receiver when the log is 80% full. If the log
becomes full, new messages overwrite the oldest messages in the log.
This system has the ability to record various events in a history log
(VISTA-20P = 100 events; VISTA-15P = 50 events). At any time, the
downloader operator can then upload the log and view or print out all
or selected categories of the log. The log can also be cleared by the
downloader operator.
The display/printout at the central station will show the date, time,
event, and description of the occurrences.
Data Entry Example: To select Alarm/Alarm Restore" and
"Open/Close", enter 9 (1+ 8); to select all events, enter #15.