Keypad Programming Fields - ADEMCO VISTA-20P Installation And Setup Manual

Hide thumbs Also See for VISTA-20P:
Table of Contents

Advertisement

Installation Instructions

Keypad Programming Fields

NOTE: Each keypad must be assigned a unique address. Keypads programmed with the same address will give
unpredictable results.
FIELD
TITLE and DATA ENTRIES
Keypad Device Address 17
*190
1st Digit – Partition Assignment:
0 = keypad disabled
1 = partition 1
2 = partition 2
3 = common
2nd Digit – Sound Option:
0 = no suppression
1 = suppress arm/disarm and E/E/ beeps
2 = suppress chime beeps only
3 = suppress arm/disarm, E/E/ beeps and
chime beeps
Keypad Device Address 18
*191
See field *190 for entries.
Keypad Device Address 19
*192
See field *190 for entries.
Keypad Device Address 20
*193
See field *190 for entries.
Keypad Device Address 21
*194
See field *190 for entries.
Keypad Device Address 22
*195
See field *190 for entries.
Keypad Device Address 23
*196
See field *190 for entries.
Exit Time Display Interval
*197
0 = no display
1-5 = seconds between display updates
Display Partition Number
*198
0 = no
1 = yes
ECP Fail Display
*199
0 = 3-digt display ("1" + device address)
1 = 2-digit fixed-display as "91"
4-12
/enabled
(VISTA-20P)
(VISTA-15P)
EXPLANATION
Keypad 2
First digit: For VISTA-20P, enter the partition in which the keypad
is located; for VISTA-15P, enter 1 to enable, or 0 to disable.
Second digit: Enter the desired sound option for this keypad.
NOTE: Address 16 is reserved for keypad 1, which is automatically
set to partition 1 with all sounds enabled.
Keypad 3
First digit: V20P = Partition (1, 2); V15P = enable (1)/disable (0).
Second digit: Enter the desired sound option for this keypad.
Keypad 4
First digit: V20P = Partition (1, 2); V15P = enable (1)/disable (0).
Second digit: Enter the desired sound option for this keypad.
Keypad 5
First digit: V20P = Partition (1, 2); V15P = enable (1)/disable (0).
Second digit: Enter the desired sound option for this keypad.
Keypad 6
First digit: V20P = Partition (1, 2); V15P = enable (1)/disable (0).
Second digit: Enter the desired sound option for this keypad.
Keypad 7
First digit: V20P = Partition (1, 2); V15P = enable (1)/disable (0).
Second digit: Enter the desired sound option for this keypad.
Keypad 8
First digit: V20P = Partition (1, 2); V15P = enable (1)/disable (0).
Second digit: Enter the desired sound option for this keypad.
If enabled, keypads display the exit time remaining after arming the
system, with display updates at the interval selected (i.e. if the exit
delay is 30 seconds and "2" is selected in this field, the keypad
display refreshes every 2 seconds, displaying 30, 28, 26, 24, etc.).
An interval greater than "1" may be necessary for some older
keypads to allow users time to enter key presses between display
updates.
If selected, the partition number is displayed in the upper-left corner
of the display. This is useful when using the GOTO partition
function.
Select "0" if using Alpha keypads and/or 3-digit Fixed-Word Display
keypads. ECP faults will display "1" plus the device address (00-30)
of device causing the fault (e.g., faults on device 07 display as "107").
Select "1" if using 2-digit Fixed-Word Display keypads (e.g., certain
6128 series keypads). If selected, ECP faults for all devices will
display as "91" on 2-digit displays, and "191" on 3-digit or Alpha
keypads.