Horizontal Terminations; Flex Vent 5" X 8 - Regency B36XT Bellavista Owners & Installation Manual

Medium dv gas fireplace
Table of Contents

Advertisement

These venting systems, in combination with the B36XT Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock
Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination
Locations" section.
®
Regency
Direct Vent (Flex) System 4 foot Termination Kit (Part# 946-615) includes all the parts needed to install the B36XT with a either a
top or rear vent.
Note: If top venting this unit, the 5" x 8" venting may only be used if venting to the minimum of 42-1/3" to centerline.
No other application is approved.
FPI Kit #
Length Contains:
#946-615
4 Feet
1)
2)
3)
4)
5)
6)
7)
8)
9)
10) vinyl siding standoff
1) 8" dia. fl exible liner (4 ft. length)
2) 5" dia. fl exible liner (4 ft. length)
3) spring spacers (4)
4) thimble
5) AstroCapXL termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" Drill Point,
Stainless Steel (4)
10) vinyl siding standoff
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex installations.
®
3) Regency
Direct Vent System (Flex) is only approved for horizontal terminations.
Note: If longer runs are required - rigid pipe must be used.
Regency Bellavista™ B36XT Gas Fireplace

HORIZONTAL TERMINATIONS

FLEX VENT 5" X 8"

8" fl exible liner (Kit length)
5" fl exible liner (Kit length)
spring spacers
thimble
AstroCap termination cap
screws
tube of Mill Pac
plated screws
S.S. screws #8 x 1-1/2" drill point
INSTALLATION
25