18) Reinstall the logs.
19) Reinstall glass door and bottom louver / full screen doors.
20) Plug the light assembly into the receptacle located on the
bottom left side of the unit.
Ground Wire
21) Turn on electrical supply - test lights.
Ground
L1
N
Regency Bellavista™ B36XT Gas Fireplace
Receptacle
LINE VOLTAGE WIRING TO RECEPTACLE IN UNIT
TO MAKE OUTLETS INDEPENDENT OF EACH OTHER
Lockwasher
Star washer
#8 Ground Lug
(mobile home
approved)
Nut
Fan
ground wire
Black
Light
Switch
Break Tab
Copper terminals
BULB REPLACEMENT
1) Follow steps 1- 4 from previous page.
2) Remove 2 screws to remove light diffuser plus gasket.
3) Replace the bulb - do not touch bulb with bare hands, use gloves or bulb
packaging to protect bulb.
4) Reinstall the gasket and light diffuser.
5) Reverse steps 4-1.
Ground
Neutral
Live
Ground
120V AC
60 Hz
ON
Rotary Speed
ELECTRICAL WORK MUST BE
Fan
Switch
PERFORMED BY A QUALIFIED
ELECTRICIAN
Ground
Red
Do Not Break Tab
on Neutral (silver terminals)
Black
Receptacle
in Unit
INSTALLATION
Optional Fan
Fan
Green
OFF
Black
Red
Red
Minimum Convection
Air Temp. Switch
Control
To Fan (see above)
Optional Accent Light
Green