Regency Bellavista B36XTE Owners & Installation Manual

Hide thumbs Also See for Bellavista B36XTE:
Table of Contents

Advertisement

Regency Bellavista
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach you gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
919-390
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Gas Fireplace
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
B36XTE
Owners &
Installation Manual
MODEL: B36XTE-10
Medium DV Gas Fireplace
Bellavista B36XT Video
www.regency-fire.com
10.22.14

Advertisement

Table of Contents
loading

Summary of Contents for Regency Bellavista B36XTE

  • Page 1 B36XTE Regency Bellavista Owners & ™ Installation Manual Gas Fireplace MODEL: B36XTE-10 Medium DV Gas Fireplace Bellavista B36XT Video www.regency-fire.com WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The Bellavista™ B36XTE has been designed to provide ® you with all the warmth and charm of a wood fireplace at the flick of a switch. The Bellavista™ B36XTE has been approved by Warnock Hersey/Intertek for both safety and efficiency.
  • Page 3: Manufactured Mobile Home Requirements

    This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. Ensure that structural members are not cut or weakened during installation. Bellavista B36XT Video Bellavista Benefits Video Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 4: Table Of Contents

    RIGID PIPE 4" x 6-5/8" ........30 Removing Valve ............59 Horizontal terminations ..........31 Installing Valve .............59 Two (2) 90 Elbows (Rigid Pipe 4" x 6 - 5/8") ....31 Main Assembly ............60 Burner Assembly ............62 The Warranty: Limited Lifetime ........63 Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 5: Copy Of Safety Decal

    The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 6: Ma Code - Co Detector

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 7: Unit Dimensions

    UNIT DIMENSIONS 40-3/8" (1025mm) 36" (914mm) 33-1/16" (838mm) 2-1/16" 40-1/2" (51mm) (1029mm) 1-3/8" (41mm) 29-7/8" (759mm) 34-3/16" (876mm) Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 8: Important Message

    2) The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code. Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 9: Installation Checklist

    Log Set Installation d. Standard Flush Door e. Fan Installation (Optional) f. Light Installation (Optional) g. Finishing Trim (Optional) 7) Final check. Diagram 1 Flat on Wall Flat on Wall Corner Recessed into Wall/Alcove Corner Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 10: Clearances

    Front to Back Wall (Maximum) Notes: 0" No Hearth Required Alcove Minimum Vent Clearances to Combustibles Horizontal Top 2" (51mm) Horizontal Side 1-1/2 " (38mm) Horizontal Bottom 1-1/2" (38mm) Vertical Vent 1-1/2" (38mm) 10 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 11: Mantel Clearances

    B36XTE From Top of Fireplace 32" 21" 17-1/2"" 13" Opening (813mm) (533mm) (445mm) (330mm) Note: Ensure the paint that is used on the mantel and the facing is "High Quality" or the paint may discolour. Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 12: Mantel Leg Clearances

    NON- COMBUSTIBLE REQUIREMENTS: Non-combustible Header (steel stud) 42" (1067mm) on edge Non-combustible Non-combustible Material 35-1/4" (895mm) 36" (914mm) 40 - 5/8" (1032mm) Min. 3” Min. 3” Framing (76mm) (76mm) See framing dimensions on next page. 12 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 13: Framing

    ** Important: Framing height requires consideration of the hearth depth. Dimension N = N + the thickness of the installed hearth. Non-Combustible Drywall Header (or other (steel stud) facing) on edge Non-Combustible Header (steel stud) on edge Non-Combustible Facing 11" (279mm) dia. Hole through wall Vent. Opening for gas connection Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 14: Wall Mount On / Off Switch

    11. Using the two (2) screws provided secure the cover plate to the Receiver. Low Voltage Junction Box Profl ame Receiver J-Box Receiver Slider Switch Wall Plate 10 ft. wire harness with 12 pin connector Diagram 1 14 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 15: Finishing

    Non-combustible Material J-style Trim or metal corner bead may be used to finish these edges Diagram 2 2 " Diagram 3 Shown with optional finishing trim Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 16: Unit Assembly Prior To Installation

    Side for “C” hole position the top facing support must be reversed. Nailing Strip Strip Top Facing Support Screw holes for Top Facing Support Nail4.eps l3.eps 16 | Regency Bellavista™ B36XTE-10 Gas Fireplace Top Facing Support Side is reversed...
  • Page 17: Conversion To Top Vent

    8 screws. See Diagram 4. Diagram 2 Heat Deflector 3) From inside the firebox, remove the baffle plate by removing 4 screws - remove top front screw first. See Diagram 3. Diagram 4 Baffle Plate Diagram 3 Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 18 - replace top front screw first. Leave loose - until rear screws installed. See Diagram 3. Diagram 8 Baffle Plate Diagram 3 Note: Reuse existing screw holes - do not make new holes. Tighten screws. 18 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 19: Vent Restrictor, Baffle & Heat Deflector Installation

    Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited. Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 20: Exterior Vent Termination Requirements

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally 20 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 21: 4" X 6-5/8" Rigid Pipe

    Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF TM-4CS Trim Plate-Black 4DT-TP 4DFPB 4DcP SV4LA TM-4TP Regency Bellavista™ B36XTE-10 Gas Fireplace Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
  • Page 22 Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com 22 | Regency Bellavista™...
  • Page 23: 5" X 8" Rigid Pipe

    - N/A from FPI Firestop Spacer 58DVA-FS 5DT-FS 5DFS TM-5LS Trim Plate-Black 58DAV-WFS 5DT-TP 5DCP TM-5TP Regency Bellavista™ B36XTE-10 Gas Fireplace Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
  • Page 24 fi re hazard. 48” (1219mm) 38-1/4” (972mm) 47-7/8” (1216mm) Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com 24 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 25: Venting Arrangements For Horizontal Terminations

    FLEX VENT OR RIGID PIPE 5" X 8" The Diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system. A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
  • Page 26: Horizontal Terminations

    10) vinyl siding standoff Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency may be used for Flex installations. 3) Regency Direct Vent System (Flex) is only approved for horizontal terminations.
  • Page 27: Rigid Pipe 5" X 8

    5" X 8" AstroCapXL™ Flex vent or approved Rigid Vent System • Max. 3 ft. horizontal run Rear Vent w/ Horizontal Termination • Can only use 5" x 8" venting • Max. 3ft. horizontal run Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 28: Astrocap Xl & Rigid Rear Vent Kit For Corner Installations

    Across the face of the unit, wall to wall 75" Vinyl Siding Standoff Inside corner to front face of the unit 37-1/2" (Optional) Astrocap Wall Thimble Pipe Length 45 elbow Rigid Pipe Adaptor 26-1/2 ” (673mm) 28 | Regency Bellavista™ B36XTE-10 Gas Fireplace 10/20/08 918-797...
  • Page 29: Venting Arrangements For Horizontal Terminations

    Horizontal vent must be supported every 3 feet. • Firestops are required at each floor level and whenever passing through a wall. • A wall thimble is mandatory for all horizontal terminations due to high temperatures. Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 30: Horizontal Or Vertical Terminations

    If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches. Note: The 4" x 6-5/8" Regency Flex Kits (946-515 & 946-516) are not approved for use with this fireplace. Only rigid pipe may be used when 4" x 6-5/8" is used.
  • Page 31: Horizontal Terminations

    5' Max. 11' Min. 8' Max. elbows is required. 7' Min. 6' Max. 12' Min. 9' Max. No Vent Restrictor Installed Lengths do not include elbow indicated. Must use reducer # 946-606 and rigid pipe adaptor #770-994. Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 32: Venting Arrangements For Vertical Terminations

    Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting to 2-14" opening ,1-5/8"opening and to 1-1/16" opening. Note: Must use optional flue adapter when using Rigid Pipe (Part # 770-994). 32 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 33: Vertical Terminations

    6' Min. 7' Max. 9' Min. required. 7' Min. 8' Max. 10' Min. No Vent Restrictor Installed Lengths do not include elbow indicated. Must use reducer # 946-606 and rigid pipe adaptor #770-994 Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 34: Venting Arrangements

    Pipe Length Co-Linear Flex Adapter Reducer #946-606 with Kit# (4 x 6-5/8 venting) 946-563 Rigid Pipe Adapter 90 Degree # 770-994 Elbow Inner Pipe Adapter with Kit# 946-563 34 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 35: Vertical Terminations

    VERTICAL TERMINATIONS CO-LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES FOR BOTH RESIDENTIAL & MANUFACTURED HOMES The shaded area in the Diagrams show the allowable vertical terminations. Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 36: Unit Installation With Horizontal Termination

    4) Level the fireplace and fasten it to the framing using nails or screws through the top and side nailing strips. Diagram 7 Diagram 2 Diagram 1 36 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 37: Unit Installation With Horizontal Termination

    Apply Mill Pac or high temperature silicone to the outer flex pipe and slip it over Vinyl Siding the outer flue collar of the vent terminal at least 1-3/8"(35mm) and fasten with the 3 Wall Thimble Screws screws. Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 38: Unit Installation With Vertical Termination

    Important: Always check for gas leaks with a soap and water solution or gas leak detector. 7) Ensure vent is vertical and secure the base Do not use open flame for leak testing. 38 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 39: Pilot Adjustment

    885 S.I.T. VALVE DESCRIPTION 1) 6 Stage flame adjustment 2) Pilot adjustment 3) Inlet Pressure Tap 4) Outlet Pressure Tap 5) Pilot Outlet 6) Main Gas Outlet 7) Main Gas Inlet Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 40: Conversion From Ng To Lp

    14) Adjust aeration accordingly.- see Pull off the pilot cap to expose the pilot manual for details. 14) orifice. Attach the label “This unit has been converted to LPG” near or on top of the serial # decal. 15) Replace yellow “NG” label with red “LPG” label. 16) Reverse steps 4 - 1. Installer Notice: 17) Check for gas leaks. These instructions must be left 18) Check inlet and outlet pressures. with the appliance. 19) Check operation of flame control. 40 | Regency Bellavista™ B36XTE-10 Gas Fireplace 09.26.14 919-437...
  • Page 41: Brick Panel Installation

    Note: Ensure that an equal space (gap) is maintained on both left panel (see step 5). the right and left side - when installing the back panel. Final Brick Panel Installation Back Panel Installed 8) Reinstall top heat defl ector (reverse Step 3). Regency Bellavista™ B36XTE-10 Gas Fireplace 09/02/08 918-774...
  • Page 42: Optional Enamel Panel Installation

    2) Install the back panel fi rst - use care when clearing the burner assembly and rear log tray, so panel is not scratched. Diagram 5 5) Repeat step 4 for left side panel. 6) Reverse step 1. Diagram 3 Diagram 6 Final Installation 42 | Regency Bellavista™ B36XTE-10 Gas Fireplace 918-807a 05/15/12...
  • Page 43: Log Set Installation

    1) Carefully remove the logs from the packaging and unwrap them. The logs are fragile, handle with care - do not force into position. Notch Note: See fi nal positioning of Log B on next page. Regency Bellavista™ B36XTE-10 Gas Fireplace 04/20/09 918-819a...
  • Page 44 7) The notch on the bottom of Log D rests against the knot on Log A (as shown below). Back of Log A Notch location on underside of Log A (runs from back - front) 44 | Regency Bellavista™ B36XTE-10 Gas Fireplace 918-819a 04/20/09...
  • Page 45 Fit Log C onto left peg on Log E - the notch on the bottom of Log C rests against the 3rd (from the left) grate post. Notch in log C Left Peg - Log E 3rd Grate Post Regency Bellavista™ B36XTE-10 Gas Fireplace 04/20/09 918-819a...
  • Page 46: Aeration Adjustment

    CAUTION: Label all wires prior to disconnection Caution: Ensure that the wires do not touch any when servicing controls. Wiring errors can cause hot surfaces and are away from sharp edges. improper and dangerous operation. 1 of 10 46 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 47: Optional Fan Installation

    8) Plug fan power cord into the Fan Control Module (FCM) then plug in the FCM. The switch is on when pushed to the left. (Shown in OFF position above) Regency Bellavista™ B36XTE-10 Gas Fireplace 09.30.14 919-439...
  • Page 48: Wiring Diagram With Optional Fan

    Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. 48 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 49: Optional Accent Light Installation

    6) From inside the fi rebox - feed the wires from the bottom of the light assembly - through the opening exposed after the removal of the cover plate. Light assembly Cable Tie wiring Regency Bellavista™ B36XTE-10 Gas Fireplace 08/13/14 918-821a...
  • Page 50 Amber glass plate covered - for use with units using stainless steel / black enamel panels as show below in Image B. Wire Clip 13) Reinstall the rear log tray - secure with 2 screws. 50 | Regency Bellavista™ B36XTE-10 Gas Fireplace 918-821a 08/13/14...
  • Page 51 4) Reinstall the gasket and light diffuser. 5) Reverse steps 4-1. LINE VOLTAGE WIRING TO RECEPTACLE IN UNIT TO MAKE OUTLETS INDEPENDENT OF EACH OTHER AC Adaptor ELECTRICAL WORK MUST BE PERFORMED BY A QUALIFIED ELECTRICIAN Regency Bellavista™ B36XTE-10 Gas Fireplace 08/13/14 918-821a...
  • Page 52: Flush Glass Door Installation

    2) Lower the flush door, then hook the 2 adjustable tension latches - close the latches to secure the flush door(See Diagram 2). Adjustable Tension Latch location Diagram 2 Note: To remove Flush Glass door reverse Steps 1 and 2. 52 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 53: Vignette Frame And Safety Screen Installation

    2. Line up tabs on mesh assembly with slots in outer frame and lower gen- 3. To remove reverse steps tly into place. Bring bottom of the mesh assembly toward the front of the appliance until it comes in contact with the magnets 10/02/14 919-440 Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 54: Optional Finishing Trim Installation

    Slide the Finishing Trim Top over the Side Trim pieces and fit the bottom bracket slots over the screws. Tighten the 3 screws to secure in place. B41XTE B36XTE 54 | Regency Bellavista™ B36XTE-10 Gas Fireplace 43-3/8" 40-1/2" Edge of Unit Finishing Trim 37-5/8"...
  • Page 55: Operating Instructions

    Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 56: Lighting Procedure

    2. Press and release the ON/OFF button on the remote handheld transmit- ter (see Diagram 2). An audible beep should be heard from the receiver. to the unit. ON/OFF Button Diagram 2 Remote shown in Manual Mode on Hi 56 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 57: Copy Of Lighting Plate Instructions

    Utilisez l'interrupteur murale ON/OFF du Brûleur ou du contrôle à distance pour éteindre le brûleur. Si le service est effectuée–vous devez débrancher l'alimentation et coupez le gaz à l'unité. DO NOT REMOVE THIS INSTRUCTION PLATE 919-401a Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 58: Maintenance Instructions

    In the event that you break your glass by impact, person. covered under warranty. purchase your replacement from an authorized Regency dealer only. Replacement glass (Part 5) The appliance and venting system must be #940-357/P) is shipped already installed into inspected before use, and at least annually, the door frame.
  • Page 59: Removing Valve

    Diagram 2: Slide burner assembly to the left and then remove. 7) Remove the 2 screws securing the rear log tray and lift out. Diagram 3 Diagram 6 Diagram 3 Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 60: Main Assembly

    Black Enamel Panels 10) 820-389 Thermodisc Bracket 12) 948-165 Adjustable Tension Latch 13) 904-731 Capscrew 1/4 - 20 x 3.5 NC Gr5 14) 940-357/P Ceramic Glass 15) 556-012 Door Frame Outerbox Assembly Firebox Assembly 60 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 61 MAIN ASSEMBLY FAN SWITCH ASSEMBLY Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 62: Burner Assembly

    Pilot Orifice - LP 578-576E/P Valve Assembly - LP 946-721 AC Adaptor 578-972 Conversion Kit LP 10) 911-006 Pilot Assembly - NG 911-007 Pilot Assembly - LP 911-004 Valve NG 911-005 Valve LP 62 | Regency Bellavista™ B36XTE-10 Gas Fireplace...
  • Page 63: The Warranty: Limited Lifetime

    Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly ® before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.
  • Page 64 Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Bellavista B36XT Video Regency™, Bellavista™,Surefire™, and AstroCap™ are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2014, FPI Fireplace Products International Ltd. All rights reserved.

Table of Contents