Mantel Clearances - Regency B36XT Bellavista Owners & Installation Manual

Medium dv gas fireplace
Table of Contents

Advertisement

Due to the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in
the diagram on the right.
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
0
Inches

Mantel Clearances

B36XT
From Top of Fireplace
Opening
Note: Ensure the paint that is used on the mantel and the facing is "High Quality" or the paint may discolour.
Regency Bellavista™ B36XT Gas Fireplace
MANTEL CLEARANCES
Mantel Clearances
14
12
10
8
6
12"
7"
B
C
A
To Floor
A
32"
(813mm)
4
2
Combustible
Non-combustible
Header
1"
(steel stud)
on edge
Non-combustible
D
7"
Standoff
Top of
Side View
Fireplace
Opening
B
C
21"
17-1/2""
(533mm)
(445mm)
INSTALLATION
D
13"
(330mm)