Safety Label; Copy Of Safety Decal - Regency B36XT Bellavista Owners & Installation Manual

Medium dv gas fireplace
Table of Contents

Advertisement

This is a copy of the label that accompanies each
Bellavista™ B36XT Direct Vent Gas Fireplace.
We have printed a copy of the contents here
for your review.
NOTE: Regency
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
-
Listed:
VENTED GAS FIREPLACE HEATER /
Certified for/Certifi e pour:
Tested to:
ANSI Z21.88-2009/CSA 2.33-2009
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
4001172
NATURAL GAS: Model B36XT-NG
Minimum supply pressure
5.0"
Manifold pressure high
3.5"
1.6"
Manifold pressure low
Orifice size
# 35
Minimum input
21,500
31,000 Btu/h
Maximum input
0-4500
Altitude
PROPANE GAS: Model B36XT-LP
Minimum supply pressure
11"
Manifold pressure high
10"
Manifold pressure low
6.4"
Orifice size
# 51
Minimum input
25,000
Maximum input
31,000 Btu/h (9.09 kW)
Altitude
0-4500
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in
the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. (Kit #576-969).
Fan Part # 576-917.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety
Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si
les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
Electrical supply/Électrique 115VAC, 1.13 A, 60Hz.
NOT FOR USE WITH SOLID FUELS. /
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas fi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
Regency Bellavista™ B36XT Gas Fireplace

COPY OF SAFETY DECAL

é
CANADA and U.S.A.
CAN/CGA-2.17-M91(R2009)
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod le B36XT-NG
WC/C.E.
(1.25kPa)
Pression d'allimentation minimum
WC/C.E.
(0.87kPa)
Pression à la tubulure d' chappement lev e
WC/C.E.
(0.40kPa)
Pression à la tubulure d' chappement basse
DMS
Grandeur de l'injecteur
Btu/h
(6.3 kW)
D bit
é
Calorifique
(9.09 kW)
D bit
é
Calorifique
ft/pi
(0-1372 m)
l'altitude
É
QUIP A L'UISINE POUR GAZ PROPANE
É
CONCU POUR ETRE POELE: Mod le B36XT-LP
Pression d'allimentation minimum
WC/C.E.
(2.74kPa)
Pression à la tubulure d' chappement lev e
WC/C.E.
(2..49kPa)
Pression à la tubulure d' chappement basse
WC/C.E.
(1.60kPa)
Grandeur de l'injecteur
DMS
D bit
é
Calorifique
Btu/h
(7.33 kW)
D bit
é
Calorifique
l'altitude
ft/pi
(0-1372 m)
NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
Duplicate S/N
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
FOYER AU GAZ À ÉVACUATION
é
é
é
é
é
minimum selon
maximum selon
é
é
é
é
é
minimum selon
maximum selon
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL
FPI Fireplace Products International Ltd. Delta, BC, Canada

SAFETY LABEL

353
Serial No./ No de serie
353
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
0" Clearance to
combustibles from:
Top, sides, bottom and rear of unit
Mantel Clearances from
D
Fireplace Opening:
C
(A) Min. 13" (330mm)
Side Wall Clearance
A
from Fireplace Opening
F
B) Min. 12" (305mm)
B
Ceiling from Top of
Fireplace Opening:
C) 36-3/4" (933mm)
Mantel Depth:
D) Max. 12" (304mm)
E
Alcove Clearances:
E) Min. Width 84" (2134mm),
DOOR SEAL: Please
F) Max. Depth 36" (914mm)
check that the door is
properly sealed
Minimum Vent Clearances:
Horizontal Top
Horizontal Side
(See Instruction Manual for
Horizontal Bottom 1-1/2" (38mm)
detailed instructions)
Vertical Vent
Made in Canada/ Fabrique au Canada
(on one side)
2" (51mm)
1-1/2" (38mm)
1-1/2" (38mm)
918-763c
5