Reading Parameters; Illumination Mode; Good Read Led Duration - Datalogic Gryphon I GFS4100 Product Reference Manual

Fixed mount linear imager barcode reader
Hide thumbs Also See for Gryphon I GFS4100:
Table of Contents

Advertisement

Reading Parameters

Illumination Mode

This feature allows you to select the illumination mode for the reader. The illumination mode
can be used to:
Selections:

Good Read LED Duration

This feature specifies the amount of time that the Good Read LED remains on following a good
read. The good read LED on time can be set within a range of 100 milliseconds to 25,500
milliseconds (0.1 to 25.5 seconds) milliseconds in 100ms increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds. A setting of 0 means that the good read
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with
3. Go to
4. Scan the barcode: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure. See Table
Product Reference Guide
increase the overall diode life
reduce power consumption
turn off the illuminator for safety purposes
Disabled: the illuminator is always off
Enabled: the illuminator is always on
Triggered: the illuminator is turned on when the reading phase starts. The illuminator is
turned off as soon as the code(s) are read or when the reading phase ends.
The triggered selection is ignored for Automatic and Test Operating
Modes.
LED stays on until the next time the trigger is pulled.
leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.
page 69
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.
Mode.
Appendix D, Keypad
33
for some examples of how to set this feature.
Reading Parameters