Code 128
ENTER/EXIT PROGRAMMING MODE

Code 128 Quiet Zones

This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank areas
at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the
label.
Code 128 Quiet Zones = No Quiet Zones
Code 128 Quiet Zones = Quiet Zone on one side
Code 128 Quiet Zones = Quiet Zones on two sides
DEFAULT
Code 128 Quiet Zones = Auto
Code 128 Quiet Zones = Virtual Quiet Zones on two sides