4. Scan the barcode: "Select No Read String."
5. Scan the hex equivalent characters from the keypad in Appendix D that represent the
6. If less than the expected string of 20 characters is selected, scan the ENTER/EXIT bar-
7. Scan the ENTER/EXIT PROGRAMMING MODE barcode once again to exit Program-
This completes the procedure.
Code Verifier
Code Verifier is available in On Line or Serial On Line and Automatic modes only. A
programmable character or string is transmitted after a successful reading phase depending on
the result of a comparison between the decoded label and a user specified label.
Code Verifier Mode
Options for this feature are:
If the code read matches the code verifier Match String then it is sent to the host through the
configured port. If it does not match the code verifier Match String, either the Wrong Code can
be sent or the defined Wrong String message can be sent indicating the error.
Match String
The string used as the match code for code verification. The Match String must be configured
to include start/stop characters and check digits, if their transmission is enabled.
It is possible to define the Match string by inserting:
No wild card characters are supported.
To set this feature:
1. Determine the desired character string (max 32).
2. Reference the ASCII Chart on the inside back cover of this manual to find the hex value
3. Go to
4. Scan the barcode: SELECT MATCH STRING.
5. Turn to
6. If less than the expected string of 32 characters are selected, scan the ENTER/EXIT bar-
Product Reference Guide
desired character string in step 1 above.
code to terminate the string.
ming Mode.
Disable: disable the Code Verifier functionality
Transmit Wrong String: the reader will transmit the wrong string to the Host.
Transmit Wrong Code: the reader wll transmit the wrong code to the Host.
any printable characters
non-printable ASCII characters available in the list inside the parameter edit box
assigned to the desired character.
Match String on page 53
enter Programming Mode.
Appendix D, Keypad
mined in step 1 above.
code to terminate the string.
and scan ENTER/EXIT PROGRAMMING MODE to
and scan the barcodes representing the hex characters deter-
Data Editing
249

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gryphon i gfs4170Gryphon i gfs4150-9

Table of Contents