Example 1:
1. $S<CR>
2. $CLFCA02<CR>
3. $Ar<CR>
Each configuration parameter setting removes the condition previously active for that
parameter.
Example 2:
1. $S<CR>
2. $HA05<CR>
3. $Ar<CR>
Example 3:
1. $+$!<CR>
Example 4:
Some parameters (ex. Strings) need to insert all the characters (typically 20 Chrs). For example,
to apply the Chr "T" (0x54) as Serial Stop String:
1. $S<CR>
2. $CSTON5400000000000000000000000000000000000000<CR>
3. $Ar<CR>
Product Reference Guide
Enter Service Mode.
Write command "Convert to Lower Case" to current configuration.
Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode.
Enter Service Mode.
Select RS232 Interface.
Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode.
Read Application Software Release.
Enter Service Mode
Select the string:"T" (54 = T) as Serial Stop Character. You must insert all the 20 Chrs (00
= one empty Chr)
Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode.
209