3. Checking Method of The SMART Test Result
Procedure:
1. After the SMART test is completed, press the [PUSH ENTER]
knob or [BACK] key to return to the "5. HDD" menu.
2. Rotate the [PUSH ENTER] knob to select the "4. SMART
Data Read(Need USB Memory)" and press the [PUSH EN-
TER] knob.
3. Rotate the [PUSH ENTER] knob to scroll the SMART data
on the liquid crystal display, and "START OF READ SMART
DATA SECTION" is displayed on the liquid crystal display.
result status
5-4.SMART Data Read
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection
activity
was never started.
Auto Offline Data Collection: Disa led.
Self-test execution status:
( 0) The previous self-test
routine completed
without error or no self-test has ever
The data was saved to USB memory
Back to HDD Menu
(Displayed characters/values in the above fi gure are example)
4. Read the result status value is displayed on the liquid crystal
display, and check the error contents at the following table.
Result status = XXh
Result
Description
status
The previous self-test routine completed without
0Xh
error or no self-test has ever been run
1Xh
The self-test routine was aborted by the host
The self-test routine was interrupted by the host
2Xh
with a hardware or software reset
A fatal error or unknown test error occurred while
the device was executing its self-test routine and
3Xh
the device was unable to complete the self-test
routine
The previous self-test completed having a test ele-
4Xh
ment that failed and the test element that failed is
not known.
The previous self-test completed having the elec-
5Xh
trical element of the test failed
The previous self-test completed having the servo
6Xh
and/or seek test element of the test failed
The previous self-test completed having the read
7Xh
element of the test failed
The previous self-test completed having a test el-
8Xh
ement that failed and the device is suspected of
having handling damage
9Xh – EXh
Reserved
FXh
Self-test routine in progress