Quick Test" Mode For Electronic Range Control; Description Of Error Codes - Maytag AER5515QA Series Service Manual

Electric freestanding range
Table of Contents

Advertisement

Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.

"Quick Test" Mode for Electronic Range Control

Follow procedure below to use the quick test mode. Entries must be made within 32 seconds of each other or the
control will exit the quick test mode.
1. Press and hold CANCEL and BROIL pads for 3 seconds.
2. Once the control has entered the "Quick Test" mode, release both pads.
3. Press each of the following pads indicated in the table below.
NOTE:
First time one of following pads is pressed it will activate the response.
The second time the pad is pressed it will deactivate the response.
Display will indicate the following:
Pad
BAKE ................................... Bake DLB and Bake relay activated
BROIL.................................. Broil DLB and Broil relay activated
KEEP WARM....................... Bake DLB and Broil DLB activated
CONVECT BAKE ................ Convection Fan on high speed
CONVECT ROAST ............. Convection Fan activated onlow speed (Jenn-Air models only)
CLEAN................................. MDL relay activated
COOK & HOLD ................... Displays last diagnostic code
FAVORITE........................... Displays EEPROM version number
TIMER ................................. Displays main code version number
CLOCK ................................ All display segments illuminated
OVEN LIGHT....................... Oven light activated
CANCEL .............................. Exit Quick Test mode
1........................................... Even segments on
2........................................... Odd segments on
3........................................... Convection Ring activated; Convection Ring DLB activated
4........................................... N/A
5........................................... N/A
6........................................... N/A
7........................................... N/A
8........................................... N/A
9........................................... N/A
0/AUTOSET......................... Steps through last 5 diagnostic codes

Description of Error Codes

Error diagnostic codes can only be viewed by entering the Diagnostic Code Display Mode.
Each error code is four digits long and is created based on the following table.
Digit
st
1
nd
2
rd
3
th
4
Diagnostic Code Display Mode can be activated by pressing and holding the AUTOSET pad for 3 seconds at
power-up. Diagnostic Code Display Mode can only be started while powering up the control.
16
!
Response
Primary System:
1 – Local to the control circuit board
3 – Sensor or meat probe
4 – Control input
9 – Door lock
Measurable:
d – Diagnostic: measurable parameter
c – Control related, replace control
Secondary System: Sequential numbering
Oven Cavity:
1 – Upper oven (or single cavity oven)
2 – Lower oven
c – Control specific
WARNING
Description
16025644
©2004 Maytag Services

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents