Maytag AER5515QA Series Service Manual page 35

Electric freestanding range
Table of Contents

Advertisement

Installation Instructions
`lkkb`qfkd qeb o^kdb
cfdrob S
PJt†‚ p‚“†€‚ `Œ Œ `Œ‹’†‘ f‹‘~‰‰~‘†Œ‹
1. Insure that the copper ground strap fp `lkkb`qba
between the middle post of the main terminal
connection block and the range chassis.
2. If bare copper or aluminum wiring is used, attach
adapter lugs as shown in figure 6. (See Bare Wire
Connection). Torque specifications are shown below.
3. The middle wire of the service cord or ground lead of
3-wire conduit jrpq connect to the neutral (middle)
©2004 Maytag Services
^``bmq^_ib J P tfob mird fkpq^ii^qflk
cfdrob S
16025644
post of the main terminal block. The other two wires of
the service cord or conduit connect to the outside
posts of the main terminal connection block. Polarity is
unimportant. If using bare wire, attach wire to
appropriate lug as shown. Torque specifications are
shown below.
4. An appropriate strain relief for service cord or conduit
jrpq be attached to the conduit plate.
A – 7