Download Print this page

"Quick Test" Mode For Electronic Range Control - Maytag MER6875BA Series Technical Information

Advertisement

Control Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless
testing requires power.

"Quick Test" Mode for Electronic Range Control

Follow the procedure below to perform the Electronic Range Control (ERC) quick test. Instructions must be entered
within 30 seconds of each other (via the touch pad) or the ERC will exit the quick test.
1. Press and hold CANCEL and BROIL pads for 3 to 5 seconds.
2. Once the control has entered the "Quick Test" mode, release both pads.
3. Press each of the following pads indicated in the table below.
Press the applicable pad once to activate the associated response.
NOTE:
Press the applicable pad a second time to deactivate the associated response.
Display will indicate the following:
Pad
BAKE....................................Bake DLB and Bake relay activated
BROIL ..................................Broil DLB and Broil relay activated
KEEP WARM .......................Bake DLB and Broil DLB activated
CONVECT BAKE .................Convection Fan on low speed
CONVECT ROAST ..............Convection Fan on high speed
CLEAN .................................MDL relay activated
COOK & HOLD ....................Displays last diagnostic code
FAVORITE ...........................Displays EEPROM version number
TIMER ..................................Displays main code version number
CLOCK.................................All display segments illuminated
OVEN LIGHT .......................Oven light activated
CANCEL...............................Exit Quick Test mode
1 ...........................................Even segments on
2 ...........................................Odd segments on
3 ...........................................Convection Ring activated; Convection Ring DLB activated
4 ...........................................N/A
5 ...........................................N/A
6 ...........................................N/A
7 ...........................................N/A
8 ...........................................N/A
9 ...........................................N/A
AUTOSET ............................Steps through last 5 diagnostic codes
Warming Zone .....................Warming Zone Relays activated
Description of Error Codes
The Diagnostic Code Display Mode allows viewing of the error diagnostic codes.
Each error code consists of four digits. The following table describes the function of each digit.
Digit
st
1
nd
2
rd
3
th
4
Diagnostic Code Display Mode may be activated at power-up by pressing and holding the AUTOSET pad for 3 to 5
seconds. Diagnostic Code Display Mode may be accessed only when applying power to the control.
July 2006
©2006 Maytag Services
!
Response
Primary System:
1 – Local to the control circuit board
3 – Sensor or meat probe
4 – Control input
9 – Door lock
Measurable:
d – Diagnostic: measurable parameter
c – Control related, replace control
Secondary System: Sequential numbering
Oven Cavity:
1 – Upper oven (or single cavity oven)
2 – Lower oven
c – Control specific
WARNING
Description
7
16027361

Advertisement