Maytag AER5712BA Series Technical Information
Maytag AER5712BA Series Technical Information

Maytag AER5712BA Series Technical Information

Electric freestanding range
Hide thumbs Also See for AER5712BA Series:

Advertisement

Electric Freestanding Range⎯Technical Information
AER5712BA*
MER5751BA*
• Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this unit.
• Refer to Service Manual 16026784 for detailed installation, operating, testing, troubleshooting, and disassembly
instructions.
All safety information must be followed as provided in Service Manual 16026784.
To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless
testing requires power.
Model
Power Source
Electrical rating, 240 V
Electrical rating, 208 V
Amperage
Frequency
Element Wattage @ 240 V
Ribbon element, dual
Ribbon element, 6 inch
Ribbon element, ceramas
Oven Wattage @ 240 V (208 V)
Bake 4 pass
Broil 4 pass
Oven Interior Dimensions in. (cm)
Height
Width
Depth
Product Exterior Dimensions in. (cm)
Height overall
Width
Depth, excluding handle
Features
Oven capacity (cubic feet)
Manual oven light
Oven window
Oven racks
Timer
Delay start
Storage drawer
Handle
Weight lbs. (kg)
Crated
*Rating of 208 VAC is approximately 80% of 240 VAC value.
November 2005
© 2005 Maytag Services
MER5752BA*
!
CAUTION
!
WARNING
AER5712BA*
MER5751BA*
10.7 kW
10.7 kW
8.1 kW
8.1 kW
40 Amp
40 Amp
60 Hz
60 Hz
2,500*
2,500*
1,200*
1,200*
N/A
N/A
2,600 (1950)
2,600 (1950)
3,000 (2250)
3,000 (2250)
16.5
(41.9)
16.5
(41.9)
23
(58.4)
23
(58.4)
18.125 (46)
18.125 (46)
46.75 (118.75) 46.75 (118.75) 46.75 (118.75) 46.75 (118.75)
29.875 (75.9)
29.875 (75.9)
25
(63.5)
25
(63.5)
4.9
4.9
Incandescent
Incandescent
Large
Standard
Yes
Yes
Yes
Yes
Yes
Yes
Removable
Removable
Standard
Standard
166
(75.3)
166
(75.3)
1
MERH752BA*
MER5752BA*
MERH752BA*
10.7 kW
10.7 kW
8.1 kW
8.1 kW
40 Amp
40 Amp
60 Hz
60 Hz
2,500*
2,500*
1,200*
1,200*
2,700*
2,700*
2,600 (1950)
2,600
(1950)
3,000 (2250)
3,000
(2250)
16.5
(41.9)
16.5
(41.9)
23
(58.4)
23
(58.4)
18.125 (46)
18.125 (46)
29.875 (75.9)
29.875 (75.9)
25
(63.5)
25
(63.5)
4.9
4.9
Incandescent
Incandescent
Large
Large
Yes
Yes
Yes
Yes
Yes
Yes
Removable
Removable
Standard
Standard
166
(75.3)
166
(75.3)
MERM752BA*
MERM752BA*
10.7 kW
8.1 kW
40 Amp
60 Hz
2,500*
1,200*
N/A
2,600
(1950)
3,000
(2250)
16.5
(41.9)
23
(58.4)
18.125 (46)
46.75 (118.75)
29.875 (75.9)
25
(63.5)
4.9
Incandescent
Large
Yes
Yes
Yes
Removable
Standard
166
(75.3)
16026688

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AER5712BA Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Maytag AER5712BA Series

  • Page 1 Storage drawer Removable Removable Removable Removable Removable Handle Standard Standard Standard Standard Standard Weight lbs. (kg) Crated (75.3) (75.3) (75.3) (75.3) (75.3) *Rating of 208 VAC is approximately 80% of 240 VAC value. November 2005 16026688 © 2005 Maytag Services...
  • Page 2: Component Testing Procedures

    Connect volt-ohms meter to Approximate H1 and H2. Time On Time Off Measure the following for voltages at MED (4-5) LO, MED, HI: 100% H1 to H2 ......... 240 VAC. If not, replace switch. 16026688 November 2005 © 2005 Maytag Services...
  • Page 3 Ribbon element, Disconnect wire leads to element and Ω 1200W measure cold resistance of terminals ... Approximately 44.3 to 48.9 Measure voltage at element....240 VAC. If voltage is not present, check wiring. November 2005 16026688 © 2005 Maytag Services...
  • Page 4: Control Testing Procedures

    The last 5 diagnostic codes will be stored display in the non-volatile memory. seconds of powering up the unit. Cycle through the codes using the See "Description of Error Codes" for More + or Less - pads. explanation. 16026688 November 2005 © 2005 Maytag Services...
  • Page 5: "Quick Test" Mode For Electronic Range Control

    Secondary System: Sequential numbering Oven Cavity: 1 – Upper oven (or single cavity oven) 2 – Lower oven c – Control specific Diagnostic Code Display Mode must be accessed within 30 seconds of powering-up the control. November 2005 16026688 © 2005 Maytag Services...
  • Page 6 Disables cooking functions 9d31 Unlock switch both locked and unlocked Nothing No action 9d41 Unlock switch neither locked or unlocked Nothing No action 9d51 Lock switch not locked or unlocked Nothing Disables Clean function 16026688 November 2005 © 2005 Maytag Services...
  • Page 7 If a function requiring latch movement is attempted while the lock switch is faulted, the control will sound an error tone and the function will be disabled. Bake Timer Broil CANCEL Keep Cook Clean Clock Delay Warm Hold M1 Control November 2005 16026688 © 2005 Maytag Services...
  • Page 8: Wiring Diagram And Schematic

    Wiring Diagram and Schematic WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power. Control Circuits 16026688 November 2005 © 2005 Maytag Services...
  • Page 9 Wiring Diagram and Schematic WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power. Wiring Diagram November 2005 16026688 © 2005 Maytag Services...

Table of Contents