Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.
Illustration
Matrix
Control Panel Assembly
Matrix
Control Panel Assembly
14
!
WARNING
Test Procedure
Continuity is indicated as follows:
1000 – 6600 Ω for Cancel pad
1000 – 15000 Ω for All other pads
16
9
8
1
Continuity is indicated as follows:
1000 – 6600 Ω for Cancel pad
1000 – 15000 Ω for All other pads
16
9
8
1
16025644
Results
Pad
Trace
1
13 & 15
2
12 & 15
3
10 & 15
4
7 & 13
5
12 & 13
6
10 & 12
7
4 & 13
8
4 & 12
9
4 & 10
0
5 & 12
Cancel
1 & 2
Convect Bake
7 & 14
Convect Roast
13 & 14
Keep Warm
4 & 7
Bake
7 & 15
Broil
4 & 5
Clean
5 & 7
Drying
11 & 12
Proofing
5 & 10
Timer
4 & 14
Clock
5 & 15
Cook & Hold
11 & 15
Favorite
5 & 13
Light
10 & 11
Pad
Trace
1
13 & 15
2
12 & 13
3
12 & 15
4
4 & 14
5
4 & 12
6
4 & 10
7
5 & 13
8
5 & 12
9
5 & 10
0
10 & 12
Cancel
1 & 2 or 3
Clock
4 & 5
Cook & Hold
4 & 7
Broil
5 & 7
Bake
10 & 11
CV Bake
4 & 13
CV Roast
7 & 14
Clean
7 & 15
Keep Warm
11 & 12
Favorites
13 & 14
Timer
5 & 14
Light
7 & 13
©2004 Maytag Services
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents