Control Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless
testing requires power.

Electronic Oven Control (EOC) III Testing Procedures

ELECTRONIC OVEN CONTROL III TESTING/PROGRAMMING PROCEDURES
Feature
Control Reset
Resets control to factory default
values.
Oven Temperature Adjustment
Determines oven cavity offset
temperature (range from -35° F to
+35° F, or -21° C to +21° C).
Time Options
Determines control time, day of
week, 12/24 hour clock.
Time Set
Determines time of day (Monday
through Sunday) to display on
control.
Day of Week
Determines day of week (Monday
thru Sunday) to display on control
12/24-Hour Clock Display
Determines 12-hour or 24-hour
clock display on control.
Clock & Day Display Disable
Determines if time of day and day
of week will display on control.
Language Display
Determines language display on
control (English, French, Spanish).
C/F (Celsius/Fahrenheit) Display
Determines temperature display on
control (C or F).
Auto Convection
When enabled, reduces the
Convection Bake and Pastry
temperatures by 25° F (-3.9° C).
Tone Options
Determines cook tones, timer
tones and volume settings.
March 2006
© 2006 Maytag Services
!
WARNING
Warm
Drawer
ATM PADS
Access Procedure
Press the Setup pad, then press the right ATM
pad until SERVICE displays. Press the left
ATM pad to select SERVICE menu options.
Press the Setup pad, then press the right ATM
pad until TEMP ADJUST displays. Press the
left ATM pad to select oven TEMP
ADJUSTMENT settings.
Press the Setup pad, then the left ATM pad to
select TIME OPTIONS.
Press the Setup pad, then the left ATM pad,
then the left ATM pad again to set the time of
day clock.
Press the Setup pad, then the left ATM pad,
then press the right ATM pad until DAY
displays. Press the left ATM pad to set the day
of the week.
Press the Setup pad, then the left ATM pad,
then press the right ATM pad until 12/24HR
displays. Press the left ATM pad to select
12/24 HR clock.
Press the Setup pad, then press the right ATM
pad until DISABLE displays. Press the left ATM
pad to select DISABLE settings.
Press the Setup pad, then press the right ATM
pad until LANGUAGE displays. Press the left
ATM pad to set LANGUAGE settings.
Press the Setup pad, then press the right ATM
pad until C/F displays. Press the left ATM pad
to select C/F settings.
Press the Setup pad, then press the right ATM
pad until AUTO CONVECT displays. Press the
left ATM pad to select AUTO CONVECT
settings.
Press the Setup pad, then press the right ATM
pad until TONES displays. Press the left ATM
pad to select TONES options.
5
Modification Procedure
Press and hold the Back and Enter pads
for 5 seconds to enter SERVICE menu
options. Press the right ATM pad to scroll
to CONTROL RESET. Press the left ATM
pad to select CONTROL RESET, then
press the left ATM pad again to reset the
control logic. Press Setup to exit.
Enter the offset temperature setting desired
using the digits pads. Press the right ATM
pad for + temperature adjustment, or the
left ATM pad for – temperature adjustment.
Press 0 to reset control back to no
temperature adjustment. Wait 3 seconds
for the control to accept the request. Press
Setup to exit.
Press the right ATM pad to scroll to the
desired function to modify.
Enter the correct time using the digits pads
and press Enter. Press the left ATM pad to
select AM or the right ATM pad to select
PM. Press Setup to exit.
Press the right ATM pad until the correct
day displays, then press the left ATM pad
to select. Press Setup to exit.
Press the left ATM pad to select 12-hour
clock, or the right ATM pad to select 24-
hour clock. Press Setup to exit.
Press the left ATM pad to select TIME, or
the right ATM pad to scroll to DAY, then
press the left ATM pad. Press the left ATM
pad to turn display on or the right ATM pad
to turn display off. Press Setup to exit.
Press the right ATM pad until the desired
language displays (English, French,
Spanish). Press the left ATM pad. Press
Setup to exit.
Press the left ATM pad to select Celsius or
the right ATM pad to select Fahrenheit.
Press Setup to exit.
Press the left ATM pad to turn on auto
convect, or the right ATM pad to turn off
auto convect. Press Setup to exit.
Press the right ATM pad to scroll to the
desired tone to modify.
16026928