Removing The Drain Pump - Whirlpool LHW0050PQ Service Manual

24'' front-loading automatic washer
Hide thumbs Also See for LHW0050PQ:
Table of Contents

Advertisement

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
Remove the top cover from the washer
(see page 4-2 for the procedure).
4.
Position the washer so that you can ac-
cess the rear panel.
5.
Remove the ten T-20 Torx screws from
the rear panel and remove the panel from
the washer.
Rear Panel Screw
Rear Panel
Drain Pump Location

REMOVING THE DRAIN PUMP

(1 of 10)
6.
Tilt the washer forward so you can access
the bottom of the washer.
7.
Remove the two 10 mm hex-head screws
from the drain pump, and then lower the
washer.
8.
Disconnect the two wire connectors from
the drain pump motor terminals.
9.
Loosen the two clamps on the inlet and
outlet hoses of the drain pump, and pull
the hoses off the pump.
Inlet
Hose
Clamp
Outlet
Hose
Clamp
4-13
Bottom Of Washer
Drain
Pump
Screws
Drain Pump
Pump Motor Wires