WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
Remove the top cover from the washer
(see page 4-2 for the procedure).
4.
Remove the rear panel (see page 4-13).
Thermostat

REMOVING THE THERMOSTAT

5.
Disconnect the two wire connectors from
the thermostat terminals.
6.
Remove the thermostat screw from the
tub and remove the thermostat and its
holder.
Thermostat Screw
Thermostat With Holder