Static Routes: SmartPath EMS sends traffic destined for 10.1.6.0/24 to 10.1.2.1.
SmartPath EMS sends traffic destined for 10.1.7.0/24 to 10.1.2.1.
Default Gateway: 10.1.1.1 (SmartPath EMS sends traffic here when there are no specific routes to a destination.)
NOTE: To set static routes after you log in to the GUI, click Home > Administration > SmartPath EMS Settings > Routing > Add,
set the destination IP address, netmask, and gateway, and then click "Apply."
When only the MGT interface is enabled, both types of management traffic use it. A possible drawback to this approach is that
you cannot separate the two types of management traffic into two different networks. For example, if you have an existing man-
agement network, you would not be able to use it for SmartPath EMS management traffic. Both SmartPath EMS and SmartPath
AP management traffic would need to flow on the operational network because SmartPath EMS would need to communicate
with the SmartPath APs from its MGT interface (see Figure 7-3). However, if the separation of both types of traffic is not an issue,
then using just the MGT interface is a simple approach to consider.
SmartPath
HiveManager
EMS
Default Gateway: 10.1.1.1 (SmartPath EMS sends all traffic to the default gateway.)
8. After you finish configuring the network settings, restart network services by entering 6 (6 Restart Network Services) and then
enter yes to confirm the action. You can now disconnect the serial cable.
Connecting to the GUI through the MGT Interface
1. Connect Ethernet cables from the MGT interface and LAN interface—if you are using it—to the network.
2. Connect an Ethernet cable from your management system to the network so that you can make an HTTPS connection to the
IP address that you set for the MGT interface.
Switch
LAN
10.1.1.8/24
MGT
10.1.2.1
10.1.2.8/24
Admin
10.1.7.34
Figure 7-2. Using both MGT and LAN interfaces.
LAN
Switch
0.0.0.0/0
MGT
10.1.1.8/24
Admin
10.1.7.34
Figure 7-3. Using just the MGT interface.
724-746-5500 | blackbox.com
Chapter 7: Using SmartPath EMS
Clusters in different subnets
Router
10.1.1.1
Router
SCP Server
10.1.6.12
Router
10.1.1.1
SCP Server
10.1.6.12
Hives in different subnets
10.1.3.0/24
10.1.4.0/24
10.1.5.0/24
Each cluster contains
Each hive contains
multiple HiveAPs.
multiple SmartPath APs
Clusters in different subnets
Hives in different subnets
10.1.3.0/24
10.1.4.0/24
10.1.5.0/24
Each cluster contains
Each hive contains
multiple HiveAPs.
multiple SmartPath APs