POSITIONING THE KEYPAD

The Keypad is suitable for mounting in dry interior
locations only.
The Keypad should be located within a protected
area so that an intruder cannot reach the Keypad
without opening a protected door or passing through
an area protected by a PIR Movement Detector. The
Keypad should be mounted in a position close to the
main entrance door so that the user access code can
be entered and the alarm system shut down within
the 15s entry time period.
Ensure that the position selected for the Keypad is
within effective range of the Siren, (refer to "Testing of
Remote Control").
Note: DO NOT fix the Keypad to metalwork or locate
the unit within 1m of metalwork (i.e. radiators, water
pipes, etc) as this could affect the radio range of
the Keypad.

INSTALLING THE KEYPAD

Ensure that the solar siren is in service mode.
1. Undo and remove the fixing screw from the bottom
edge of the Keypad and remove the wall mounting
plate.
2. Using the mounting plate as a template, mark the
positions of the two fixing holes on the wall. A small
spirit level will ensure a perfect level.
3. Fix the mounting plate to the wall using the two
18mm No.4 screws and 25mm wall plugs as
required, (a 5mm hole will be required for the wall
plugs). Do not over-tighten the fixing screws as
this may distort or damage the mounting plate.
4. Undo and remove the four fixing screws in the rear
of the Keypad and remove the rear cover.
5. Connect the PP3 Alkaline battery to the battery clip.
6. Configure the Keypad as described below and
then replace the rear cover and fixing screws.
7. Refit and secure the Keypad onto the wall mounting
plate. Do not over-tighten the fixing screws.
Note: The Keypad is supplied with a default User
Access Code of: 1 2 3 4. However, for security
reasons, it is recommended that this code is
changed to another four digit number which only
you and other users of the system know.
8
Jumper Link
(must be removed)
Anti-Tamper
Switch

CONFIGURING THE KEYPAD

1. Located above the battery clip is a row of 8 DIP
switches 1 - 8. These switches set the House
Code for the Remote Control and must be set
to the same ON/OFF combination as the DIP
switches in the Solar Siren.
2. Ensure that the jumper link located in the top left
corner of the PCB (shown in the above diagram)
is removed for use with this alarm system.
CHANGING THE USER ACCESS CODE
When using the Keypad the keys must be pressed
firmly and within five seconds of each other. If you
make a mistake, wait five seconds and recommence
programming from the beginning of the sequence.
To change the User Access Code, press the following
keys in sequence:
1. Press
1
2. Enter default (or current) User Access code:
1
2
3
3. Press
- The 'on-air' LED will flash twice
1
4. Enter new User Access code:
?
?
?
5. Press
- the 'on-air' LED will flash three times
1
to confirm the setting has been accepted. If the light
Wall Fixing
Plate
Fixing
Screw
House Code
DIP Switches
4
?
SA1/SA2/SAC1