3.3.5 Free-run VGA Mode (A504k/kc Only)

Figure 3-23: Free-run VGA Mode
Effective exposure = n - 15.8 µs ... n + 15.8 µs
Effective exposure time can only occur in multiples of 15.8 µs.
Timer 1 must be set to a minimum of 10 µs and to a maximum of 16645 µs.
With very low exposures, use flash light.
k
Basler A500
PRELIMINARY
Basic Operation and Features
(n = exposure set by Timer 1)
3-25