3.3.4.4 Free-run Mode with Synchronous Timing 2
Figure 3-22:Free-run, Programmable Mode - Exposure Start and Stop with Frame Valid High
If the exposure starts and ends while Frame Valid is high (see Table for values n to z):
• Actual length of exposure time = n - x + y
The actual length of exposure time can only occur in multiples of z µs.
n
x
y
z
3-24
PRELIMINARY
k/kc
k/kc
A504
A501
exposure set by Timer 1
≤
≤
2 µs
7 µs
≤
≤
2 µs
7 µs
2 µs
13.2 µs
k
Basler A500