Area Of Interest Starting Line; Area Of Interest Height In Lines - Basler A500k User Manual

Hide thumbs Also See for A500k:
Table of Contents

Advertisement

Configuring the Camera

4.2.4.11 Area of Interest Starting Line

Purpose:
To set the starting line for the Area of Interest or to read the current starting pixel setting.
See Section
Type:
This is a read or write command.
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:

4.2.4.12 Area of Interest Height in Lines

Purpose:
To set the height in lines for the Area of Interest or to read the current height setting. See
Section
Type:
This is a read or write command.
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:
4-18
PRELIMINARY
3.9
for details.
Cmd-ID
R/W-Flag
0xA8
Cmd-ID
R/W-Flag
0xA8
Cmd-ID
R/W-Flag
0xA8
None
Byte 1
Low byte of the starting pixel setting
Byte 2
High byte of the starting pixel setting
The starting line setting can range from 0x0000 to 0x03FF. For color
cameras, it can only be set in steps of 2. (Note that the starting pixel = n +1
where n is the value of the starting pixel setting.)
3.9
for details.
Cmd-ID
R/W-Flag
0xAA
Cmd-ID
R/W-Flag
0xAA
Cmd-ID
R/W-Flag
0xAA
None
Byte 1
Low byte of the length in pixel setting
Byte 2
High byte of the length in pixel setting
The height in lines setting can range from 0x0002 to 0x0400. For color
cameras, the height can only be set in steps of 2 starting at 0x0002.
Data Length
1
2
Data Length
0
2
Data Length
0
2
Data Length
1
2
Data Length
0
2
Data Length
0
2
Data
-
Data
2 Bytes
Data
2 Bytes
Data
-
Data
2 Bytes
Data
2 Bytes