Exsync, Edge-Controlled Mode With Synchronous Timing 1 - Basler A500k User Manual

Hide thumbs Also See for A500k:
Table of Contents

Advertisement

Basic Operation and Features

3.3.1.2 ExSync, Edge-controlled Mode with Synchronous Timing 1

Figure 3-9: ExSync, Edge-controlled Mode - Exposure Start and Stop with Frame Valid High
If the exposure starts and ends while Frame Valid is high (see Table for values n to y):
• The actual start of exposure can be x µs later than the rise of the ExSync signal.
• Actual length of exposure time = n µs - y µs
n
x
y
3-10
PRELIMINARY
k/kc
k/kc
A504
A501
exposure set by ExSync
3.3 ... 5.2 µs
27 ... 40 µs
3 µs
12.8 µs
k
Basler A500

Advertisement