Camera Link Implementation In The A500K - Basler A500k User Manual

Hide thumbs Also See for A500k:
Table of Contents

Advertisement

2.3 Camera Link Implementation in the A500
The A500
uses a National Semiconductor DS90CR287 as a Camera Link transmitter. For a
k
Camera Link receiver, we recommend that you use the National Semiconductor DS90CR288, the
National Semiconductor DS90CR288A or an equivalent. Detailed data sheets for these
components are available at the National Semiconductor web site (www.national.com). The data
sheets contain all of the information that you need to implement Camera Link, including
application notes.
Note that the timing used for sampling the data at the Camera Link receiver in the
frame grabber varies from device to device. On some receivers, TTL data must be
sampled on the rising edge of the receive clock, and on others, it must be sampled
on the falling edge. Also, some devices are available which allow you to select either
rising edge or falling edge sampling. Please consult the data sheet for the receiver
that you are using for specific timing information.
The A500
uses a National Semiconductor DS90LV048A differential line receiver to receive the
k
RS-644 camera control input signals and the serial communication input signal defined in the
Camera Link specification. A DS90LV047A differential line transmitter is used to transmit the
serial communication output signal defined in the specification. Detailed spec sheets for these
devices are available at the National Semiconductor web site (www.national.com).
The A504
k/kc
three differential line transmitters. The schematic in Figure 2-5 shows the interface for the A504
kc.
The schematic in Figure 2-6 shows the interface for the A501
the frame grabber interface. The A501
line transmitter.
k
Basler A500
PRELIMINARY
uses the full configuration of Camera Link with three differential line receivers and
k/kc
uses one differential line receiver and one differential
k/kc
Camera Interface
k
and a typical implementation for
k/
2-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

A500k seriesA504kA504kcA501kA501kc

Table of Contents