3.3.2.2 ExSync, Level-controlled Mode with Synchronous/Asynchronous
Timing
Figure 3-12: ExSync, Level-controlled Mode - Exposure Start when Frame Valid is High, Exposure
Stop when Frame Valid is Low
If the exposure starts while Frame Valid is high, and ends while Frame Valid is low (see Table for
values n to z):
• The actual start of exposure can be x µs later than the falling of the ExSync signal.
• Actual length of exposure time = n - y µs .... n + z µs
n
x
y
z
k
Basler A500
PRELIMINARY
k/kc
k/kc
A504
A501
exposure set by ExSync
1.8 µs to 5 µs
6.8 µs to 20 µs
2 µs
13 µs
0 µs
0.2 µs