4.2.4.9 Area of Interest Starting Column

Purpose:
To set the left starting column for the Area of Interest or to read the current starting column
setting. See Section
Type:
This is a read or write command.
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:The starting column can range from 0x0000 to 0x04F6. It can only be set in steps of 10.
When you set column n using this command, the actual starting column will be n + 1. For example, if
you set the starting column to 0 with this command, the actualstarting column =0 +1 =1.

4.2.4.10 Area of Interest Width in Columns

Purpose:
To set the width in columns for the Area of Interest or to read the current width setting. See
Section
Type:
This is a read or write command.
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:
k
Basler A500
PRELIMINARY
3.9
for details.
Cmd-ID
R/W-Flag
0xA9
Cmd-ID
R/W-Flag
0xA9
Cmd-ID
R/W-Flag
0xA9
None
Byte 1
Low byte of the starting pixel setting
Byte 2
High byte of the starting pixel setting
3.9
for details.
Cmd-ID
R/W-Flag
0xAB
Cmd-ID
R/W-Flag
0xAB
Cmd-ID
R/W-Flag
0xAB
None
Byte 1
Low byte of the length in pixel setting
Byte 2
High byte of the length in pixel setting
The width in columns can range from 0x000A to 0x0500. The width can only
be set in steps of 10.
Data Length
1
2
Data Length
0
2
Data Length
0
2
Data Length
1
2
Data Length
0
2
Data Length
0
2
Configuring the Camera
Data
-
Data
2 Bytes
Data
2 Bytes
Data
-
Data
2 Bytes
Data
2 Bytes
4-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

A500k seriesA504kA504kcA501kA501kc

Table of Contents