Flash Trigger Signal - Basler A500k User Manual

Hide thumbs Also See for A500k:
Table of Contents

Advertisement

Camera Interface
This diagram assumes that the area of interest feature is not being used. With the area of interest feature enabled, the
number of pixels transferred could be smaller.
Figure 2-10: 8 Bit output Mode with Programmable Exposure for the A501k/kc

2.5.7 Flash Trigger Signal

This signal can be programmed via the FlashCtrl register (see section 4.2.4.14). Six different
options are programmable:
• The FlashOut trigger signal can be deactivated, that is, low.
• It can be tied to an "Effective Exposure" signal that is generated internally. This means that
the FlashOut signal goes high when exposure starts and it goes low when exposure stops,
regardless of the exposure mode chosen. As an option, the polarity of FlashOut can be
inverted.
• The signal can be tied to the external ExFlash input signal provided by the framegrabber. As
an option, the polarity of FlashOut can be inverted.
• FlashOut can be permanently high.
2-22
PRELIMINARY
k
Basler A500

Advertisement

Table of Contents
loading

This manual is also suitable for:

A500k seriesA504kA504kcA501kA501kc

Table of Contents