Electrical System - Volvo EC330B Operator's Manual

Hide thumbs Also See for EC330B:
Table of Contents

Advertisement

S84269
Service and maintenance

Electrical system

Rules for batteries
See Batteries on page 128.
Charging batteries
See Charging batteries on page 129.
Alternator
Alternator belt tension
Check the belt tension daily.
WARNING!
The engine must be stationary when checking the belt
tension, rotating parts can cause injuries.
Checking
Press the center between the fan pully and the alternator pully with
a force of 10 kgf. If the slack is 9.5 ~ 12.7 mm, the tension is nor-
mal.
Adjusting
The belt tension will be adjusted automatically by the auto tension-
er.
If the belt tension is abnormal, check for damage of the auto ten-
sioner, or belt specification.
Sensitivity of alternator
The alternator installation is sensitive to incorrect connection,
therefore, always follow the installation instructions below:
Disconnection
– Battery and alternator cables must not be disconnected while
the engine is running. A fault may then arise in the alternator
and the electronics.
– Disconnect and insulate the battery cables before carrying out
any work on the alternator equipment.
149