Oil Bath Air Cleaner (Option); Checking Screen Filter Service; Servicing The Body Assembly - Volvo EC330B Operator's Manual

Hide thumbs Also See for EC330B:
Table of Contents

Advertisement

Service and maintenance
142

Oil bath Air cleaner (option)

Oil bath Air cleaner (option)

Checking screen filter service

Check the outside, inside oil (9.4Liters) cup daily.
The removable and fixed filters are the most sensitive operational
parts of the air cleaner. Unless they are kept clean, the air cleaner
cannot function properly. A plugged filter not only leads to exces-
sive engine wear, but can also cause loss in engine power.
The removable screen filter assembly (if used) should be removed
from the oil cups and inspected daily or at each oil cup service.
S82219
A
Air cleaner housing
B
Screen filter
C
Inner oil cup
D
Oil cup

Servicing the body assembly

A
The lower portion of the body assembly should be inspected each
time the air cleaner is serviced. If there is any sign of build-up or
plugging, the body assembly should be removed and cleaned. At
B
least once a year, remove the body assembly and perform the fol-
lowing service steps:
C
D
1 Remove the oil cup and removable filter (if used).
S82270
– Reassemble inner cup in outer cup and refill both cups to indi-
cated oil level. (9.4 liters)
– The same oil specified for the engine crankcase is generally ac-
ceptable.
2 Inspect filter with the aid of a lamp
– Hold it up to a strong light. An even, bright pattern of light
through the wire element means it is clean.
S82271
3 Wash filter if needed
– If element is plugged with dirt, lint or chaff (even partially), wash
thoroughly with solvent.
S82272