Engage Cable Specifications - enphase M215 Installation And Operation Manual

Enphase microinverter
Hide thumbs Also See for M215:
Table of Contents

Advertisement

Topic
Compatibility
Dimensions not including mounting bracket (approximate)
Weight
Enclosure environmental rating
Torque specifications for fasteners
(Do not over torque.)
Torque specification for 10/32 ground cleat
(Do not over torque.)
Cooling
Communication
Standard warranty term
Compliance
Integrated DC disconnect
Integrated AC disconnect

Engage Cable Specifications

Specification
System temperature range (ambient)
Cable temperature rating
Cable rating
Conductor insulator rating
Environmental protection rating
UV exposure rating
Compliance
Conductor size
Cable diameter
Minimum bend radius
Drop connector dimensions
Terminator cap dimensions
28
Enphase M215 Microinverter Parameters
Features and Specifications
 2013 Enphase Energy Inc.
M215 Installation and Operation
Unit
Pairs with most 60-cell PV modules
17.3 cm x 16.4 cm x 2.5 cm (6.8" x 6.45" x 1.0")
3.5 Lbs (1.6 Kg)
NEMA 6
6 mm (1/4") mounting hardware: 5 N m (45 to
50 in-lbs) minimum
8 mm (5/16") mounting hardware: 9 N m (80
to 85 in-lbs) minimum
2 N m (20 to 25 in-lbs) minimum
Natural convection: no fans
Power line
http://enphase.com/warranty
UL1741, IEEE1547, FCC Part 15 Class B
CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01
The DC connector has been evaluated and
approved for use as the load-break disconnect
required by the NEC.
The AC connector has been evaluated and
approved for use as the load-break disconnect
required by the NEC.
Value
-40C to +65C (-40F to 149F)
90C Dry / 90C Wet
TC-ER
THWN-2
IEC 60529 IP67
UL 746 C, F1
UL1741; CAN/CSA C22.2 Nos. 0, 21, 42, 65, 153,
182.1, 182.2, and 182.3; IEC 60529 IP67
12AWG
1.25 cm (0.49")
4.75 inches (12 cm)
11.8 cm x 6.0 cm x 3.2 cm
(4.64" x 2.36" x 1.25")
3.6 cm diameter x 5.1 cm tall (1.4" x 2")
Min
Typical
Max
141-00012 Rev 05