Engage Cable Specifications
Specification
System temperature range (ambient)
Cable temperature rating
Cable type
Cable conductor insulator rating
Environmental protection rating
UV exposure rating: terminator, Engage Coupler, and drop
connector body
Sunlight resistance (cable)
Compliance
Conductor size
Cable diameter
Minimum loop size
Drop connector dimensions
Terminator cap dimensions
37
2015 Enphase Energy Inc. All rights reserved.
C250 System Installation and Operation
Value
-40ºC to +65ºC (-40ºF to 149ºF)
90ºC Dry / 90ºC Wet
TC-ER
THWN-2
IEC 60529 IP67
UL 746 C, F1
UL 1277
UL486A/B, UL 514C, UL6703, UL 9703, IEC
60529 IP67, CAN/CSA 22.2 No. 21, 182.3
12 AWG
11.75mm (0.463")
4.75 inches (12 cm)
11.8 cm x 6.0 cm x 3.2 cm (4.64" x 2.36" x 1.25")
3.6 cm diameter x 5.1 cm tall (1.4" x 2")
141-00025 Rev 03