Technical Data

Technical Considerations

The Enphase M215 Microinverters are electrically compatible with most 60-cell PV modules. Be sure to
verify the voltage and current specifications of your PV module match those of the microinverter. For
more information, refer to our list of compatible PV modules at http://www.enphase.com/support.
WARNING: You must match the DC operating voltage range of the PV module with the
allowable input voltage range of the Enphase Microinverter.
WARNING: The maximum open circuit voltage of the PV module must not exceed the
specified maximum input voltage of the Enphase Microinverter.
The output voltage and current of the PV module depends on the quantity, size and temperature of the
PV cells, as well as the insolation on each cell. The highest PV module output voltage occurs when the
temperature of the cells is the lowest and the PV module is at open circuit (not operating). The maximum
short circuit current rating of the PV module must be equal to or less than the maximum input DC short
circuit current rating of the microinverter.

M215 Specifications

Topic
MPPT voltage range
Operating range
Maximum DC input voltage
Minimum / Maximum start voltage
Maximum DC input short circuit current
Maximum DC input current
Ground fault protection
Maximum input source backfeed current to input source
26
Enphase M215 Microinverter Parameters
DC Parameters
 2013 Enphase Energy Inc.
M215 Installation and Operation
Unit
Min
Typical
V
22
V
16
V
V
22
A
A
mA
A
Max
36
36
45
45
15
10.5
1000
0
141-00012 Rev 05