Clear - SoundCraft Si Performer User Manual

Digital live sound console
Hide thumbs Also See for Si Performer:
Table of Contents

Advertisement

CLEAR

The CLEAR facility allows channels, buses or logical groups of channels to be reset to their
factory defaults. The operation is instigated by holding the CLEAR key while pressing one of the
following keys:
HPF — Sets HPF OFF and sets Filter value to Factory Default
Gate — Sets GATE OFF and sets Gate values to Factory Default
Comp — Sets COMP OFF and sets Comp values to Factory Default
EQ — Sets EQ ON and sets EQ values to Factory Default
SELect — Sets all channel audio parameters on SELected channel to Factory Default
NOTE: Patching and naming is NOT included in resetting a channel.
GLOBAL GAIN — On current layer sets all input gains on to factory default for selected
source type, +5dB for mic sources, 0dB trim for line sources
GLOBAL FILT — On current layer sets all HPF OFF and sets all filter values to factory default
GLOBAL PAN — On current layer sets all PAN or BAL controls to centre
MUTE MASTER 1—8 — Clears ALL slaves assigned to MUTE GROUP 'n'; console must be
in mute set-up for this function to operate
VCA MASTER + [MUTE MASTER 1—8] — Clears ALL slaves assigned to VCA master 'n';
console must be in VCA set-up for this function to operate
MIX 1—14 — Sets sends from all channels to MIX 'n' to Factory Default
MTX 1—4 — Sets sends from all buses to MTX 'n' to Factory Default
FX 1—4 — Sets sends from all channel to FX 'n' to Factory Default
GEQ HI or LO — Sets all GEQ bands to 0dB for SELected bus NOTE: Not all functions are
present in all modes e.g. Buses have no HPF function, in these events the action has no
function.
NOTE: Not all functions are present in all modes e.g. Buses have no GATE function; in
these events the action has no function.