Programming Parameters
Serial Parameters
The PT40 is pre-configured at the factory with the parameter settings for serial
communications found in
Table E-7. Default Parameter Settings for Serial Communications
Baud rate
Data bits
Parity
Stop bits
Enable Xon/Xoff
Linefeed
Protocol
End of Record Character
Timeout
Table E-8
page D-12
Table E-5 on page E-8
acters. Use the Code 39 equivalents when creating bar codes for programming.
For a complete listing of parameters and defaults, refer to
eters on page E-1
Table E-8. Serial Parameters
E-12
Parameter
specifies serial parameters. Refer to
for bar codes to set serial parameters.
includes Code 39 and ASCII equivalents for serial char-
.
ID #
Parameter
C1
Baud rate
C2
Data bits
C3
Parity
C4
Stop bits
Xon/Xoff hand-
C5
shaking
.
Table E-7
Default Setting
9600
8
None
1
Off
None
CR with checksun &
ACK/NAK response
CR
1 second
Serial Parameters starting on
Description
Determines the communication speed. The setting for the
PT40 must match the setting that the host computer uses.
Specifies the number of data bits in each character.
Specifies the parity of the data characters.
Selects the minimum space between data characters.
Used for software data-flow control. With this option enabled,
the PT40 transmits an Xoff character when its serial input
buffer has fewer than ten characters of free space. Once all the
data in the serial buffer is processed, the PT40 transmits an
Xon character.